  • Page 1 Blood Pressure Monitor Trilingual Instruction Guide – MODEL UA-789 E n g l i s h • Fra n ç a i s • E spa ño l...
  • Page 3: Important Information

    Alkaline batteries recommended. PRECAUTIONS The UA-789 is designed to be used at home, by those who are eighteen (18) years and older, to monitor blood pressure (systolic and diastolic) and pulse rate. It is not designed for ambulatory use.
  • Page 4 Fast. Easy. Accurate. Congratulations on purchasing a state-of-the-art LifeSource ® blood pressure monitor—one of the most technologically advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. Physicians agree that daily self-monitoring of blood pressure...
  • Page 5: Table Of Contents

    HoW Ua-789 WorKS . . . . . . . . . . . . . . . . . . .
  • Page 6: What Display Symbols Mean

    There is an air leak in the cuff or monitor. The pulse is not detected cor- rectly. Cuff Inflation Meter Pressure Rating Indicator™ LifeSource Health Line (toll-Free): 1-888-726-9966 recommended action Measurement is in progress, remain as still as possible. Take measurement again and consult with your physician.
  • Page 7: Monitor Components

    SYSTOLIC PRESSURE DIASTOLIC PRESSURE PRESSURE RATING INDICATOR CUFF INFLATION METER IRREGULAR HEARTBEAT PULSE RATE AIR HOSE BATTERY COVER in Canada - auto Control medical (toll-Free): 1-800-461-0991 MONITOR COMPONENTS MEMORY BUTTON AC ADAPTER jACk START BUTTON CLOCk BUTTON EXTRA LARGE CUFF AIR CONNECTOR PLUG AIR SOCkET BATTERY COMPARTMENT...
  • Page 8: How Ua-789 Works

    HoW Ua-789 WorKS LifeSource® blood pressure monitors are easy to use, accurate and digitally display full measurement readouts. Our technology is based on the “oscillometric method” – a noninvasive blood pressure determination. The term “oscillation” refers to any measure of vibrations caused by the arterial pulse.
  • Page 9: Selecting The Correct Cuff Size

    Using the correct cuff size is important for an accurate reading. A cuff that is too large will produce a reading that is lower than the correct blood pressure; a cuff that is too small will produce a reading that is higher than the correct blood pressure.
  • Page 10: Taking Your Blood Pressure

    YoUr BLooD prESSUrE Adjusting the Built-in Clock The UA-789 monitor has a built-in clock that gives you the time and date and can tell you when a blood pressure reading stored in memo- ry was taken. We recommend that you adjust the clock prior to use. To adjust the clock, follow these simple steps: Press and hold the clock button until the digits start blinking.
  • Page 11 Setting the Alarm The UA-789 monitor allows you to set up to three alarms per day to notify you when to take your blood pressure. To set the alarm(s): Press and hold the clock button until the year digits start blinking. Then press and release the memory button.
  • Page 12 Cuff Size Indicator on the LifeSource AccuFit™ Cuff The LifeSource AccuFit™ cuff has an indicator which tells you wheth- er you are using the correct cuff size or not. Place the cuff on your arm (see Page E-9 to learn how to put the cuff on correctly) and if the Index Mark falls within the Proper Fit Range, you are using the cor- rect cuff size.
  • Page 13 Now you are ready. Follow these simple steps: Sit comfortably with your left arm resting on a flat surface so that the center of your upper arm is at the same height as your heart. Lay left arm on the table with palm up. Place the cuff on your upper arm.
  • Page 14 Release the START button when the desired number is reached. 280 mmHg is the highest pressure level the monitor can reach. Measurement will then begin. Continue to measure your blood pressure as described on Page E-8. E-10 SYSTOLIC DIASTOLIC PULSE LifeSource Health Line (toll-Free): 1-888-726-9966...
  • Page 15: What Is An Irregular Heartbeat

    The UA-789 monitor provides a blood pressure and pulse rate mea- surement even when an irregular heartbeat occurs. The irregular heartbeat symbol an irregular heartbeat has occurred during measurement. An irregular heartbeat is defined as a heartbeat that varies by 25% from the aver- age of all heartbeat intervals during the blood pressure measurement.
  • Page 16: About Average Reading

    ABOUT AvERAGE READING The UA-789 provides an average blood pressure reading based on the total measurements stored in memory. When tak- ing a measurement, the average blood pressure reading will appear and the number of measurements stored in memory will flash several times before the cuff begins to inflate.
  • Page 17: About Memory

    This monitor automatically stores up to sixty (60) blood pressure and pulse measurements in memory. Measurements stored in memory are assigned an index number in the order of the newest to the oldest. To retrieve readings, follow these simple steps: When the display screen is showing only the time, press and quickly release the Memory ("M") button.
  • Page 18: Using The Monitor With Ac Adapter

    USING THE MONITOR WITH AC ADAPTER The UA-789 has an AC adapter jack to allow you to supply power from an outlet in your home. The UA-789 monitor is only compatible with the included LifeSource AC Adapter (part # TB-235). The use of any other AC adapter may damage your UA-789 monitor and will void your warranty.
  • Page 19: About Blood Pressure

    What is Blood pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts; diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg). What affects Blood pressure? Blood pressure is affected by many factors: age, weight, time of day, activity level, climate, altitude and season.
  • Page 20: Assessing High Blood Pressure For Adults

    Systolic (mmHg) less than 120 less than 130 130-139 greater than or equal to LifeSource Health Line (toll-Free): 1-888-726-9966 Diastolic (mmHg) less than 80 80-89 90-99 greater than or equal to Diastolic (mmHg) less than 80...
  • Page 21: What Is Hypertension

    What is Hypertension? Hypertension (high blood pressure) is the diagnosis given when read- ings consistently rise above normal. It is well known that hyperten- sion can lead to stroke, heart attack or other illness if left untreated. Referred to as a “silent killer” because it does not always produce symptoms that alert you to the problem, hypertension is treatable when diagnosed early.
  • Page 22 Keys to Successful monitoring: Blood pressure fluctuates throughout the day. We recommend that you are consistent in your daily measurement routine: • Measure at the same time every day. • Sit in the same chair/position. • Do not cross legs and keep your feet flat on the floor. • Relax for 5 minutes before measurement. • Use the correct cuff size to get an accurate reading. • Sit still during measurement – no talking, eating or sudden movements. • Record your measurement in a logbook. E-18 LifeSource Health Line (toll-Free): 1-888-726-9966...
  • Page 23 Establishing Baseline measurements The most important method to get an accurate blood pressure mea- surement is consistency. To get the most benefit out of your monitor, it is important to establish a “baseline measurement.” This helps build a foundation of measurements that you can use to compare against future readings.
  • Page 24: Troubleshooting

    The healthcare professional may be using a different sized cuff. Your measurements may be elevated by white coat hypertension LifeSource Health Line (toll-Free): 1-888-726-9966 Corrective action Replace all batteries with new ones. Alkaline batteries recommended. Reinstall the batteries with negative and positive...
  • Page 25: Specifications

    ......UA-789 model ......Oscillometric type .
  • Page 26: Contact Information

    Blood pressure Cuffs Stethoscopes personal Health Scales Digital thermometers this LifeSource blood pressure product is covered by a Lifetime Warranty. See warranty card for details. Visit our web site at www.LifeSourceonline.com For more information regarding use, care or servicing of your blood pressure monitor, contact: A&D Medical...
  • Page 27 San Jose, CA 95131 1-888-726-9966 www.LifeSourceOnline.com LifeSource is a registered trademark and Pressure Rating Indicator, AccuFit, and HeartWise are trademarks of A&D Medical. Pressure Rating Indicator is patent pending. ©2007 A&D Medical. All rights reserved. Specifications subject to change without notice.

This manual is also suitable for:

Lifesource ua-789Lifesource ua-789ac

Table of Contents