Trane 2TWB0012-036AA Installer's Manual

Advertisement

Quick Links

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information
pack upon completion of work.
These instructions do not cover all variations in
systems nor provide for every possible contingency to
be met in connection with installation. All phases of
this installation must comply with NATIONAL, STATE
AND LOCAL CODES. Should further information be
desired or should particular problems arise which are not
covered sufficiently for the purchaser's purposes, the matter
should be referred to your installing dealer or local distributor.
A. GENERAL
The following instructions cover 2TWB0012-036AA Heat
Pump Units.
NOTE:
These outdoor units may be used with indoor units
equipped with Thermostatic Expansion Valve or Accutron™
Flow Control Check Valve (F.C.C.V.) assembly for refrigerant
flow control only.
Check for transportation damage after unit is uncrated.
Report promptly, to the carrier, any damage found to the unit.
To determine the electrical power requirements of the unit,
refer to the nameplate of the unit. The electrical power
available must agree with that listed on the nameplate.
®
The Weathertron
Heat Pump has been designed and
manufactured to withstand and operate in severe winter
conditions. However, there are precautionary steps which
should be taken at the time of installation which will help
assure the efficient operation of the unit. It is recom-
mended that these precautions be taken for units
being installed in areas where snow accumulation and
prolonged below freezing temperatures occur.
1. Units should be elevated 3 to 12 inches above the pad or
rooftop, depending on local weather. This additional
height will allow better drainage of snow and ice (melted
during defrost cycle) prior to its refreezing. This should
prevent a build-up of ice around the unit which occurs
when unit is not elevated. Insure that drain holes in
unit base pan are not obstructed preventing
draining of defrost water.
2. If possible, avoid locations that are likely to accumulate
snow drifts. If not possible, a snow drift barrier should be
installed around the unit to prevent a build-up of snow
on the sides of the unit and should be of sufficient
distance from the unit to prevent restriction of airflow to
and from the unit. Also allow for proper maintenance
Installer's Guide
Heat Pumps
2TWB0012-036AA
1
space. The barrier should be constructed of materials
which will blend in with the building design.
3. Avoid locating the unit where condensation and freezing
of defrost vapor may annoy the customer. For instance,
installing the unit under a bedroom, kitchen, or picture
window may be annoying to the customer since conden-
sate and fog will occur during the defrost cycle.
4. Avoid locating the unit under the eaves or other over-
head structures as sizeable icicles may form and the unit
may be damaged by these falling icicles.
B. LOCATION AND PREPARATION
OF THE UNIT
1. When removing unit from the pallet, notice the tabs on
the basepan. Remove tabs by cutting with a sharp tool as
shown on page 2, Figure 2, and slide unit off of pallet.
2. The unit should be set on a level support pad at least as
large as the unit base pan, such as a concrete slab. If this
is not the application used please refer to application
bulletin SSC-APG002-EN.
3. The support pad must NOT be in direct contact with any
structure. Unit must be positioned a minimum of 12"
from any wall or surrounding shrubbery to insure
adequate airflow. Clearance must be provided in front of
18-BC52D5-5
5 FT. ABOVE UNIT-UNRESTRICTED

Advertisement

Table of Contents
loading

Summary of Contents for Trane 2TWB0012-036AA

  • Page 1 A. GENERAL The following instructions cover 2TWB0012-036AA Heat Pump Units. NOTE: These outdoor units may be used with indoor units equipped with Thermostatic Expansion Valve or Accutron™...
  • Page 2: Installing Refrigerant Lines

    BRAZE TYPE INDOOR END LIQUIID LINE SERVICE VALVE SEALING CAP ACCUTRON COMPONENTS ADAPTER FLOW CONTROL CHECK VALVE (F.C.C.V.) ORIFICE BODY AS SHIPPED FIELD SUPPLIED LIQUID LINE 18-BC52D5-5 © 2010 Trane...
  • Page 3 Installer’s Guide NOTICE: GAS LINE SERVICE VALVE Precautions should be taken to avoid heat damage to basepan during brazing. It is recommended to keep the flame directly off of the basepan. 7. Use a Dry Nitrogen Purge and Brazing Alloy without flux when brazing the field line to the copper factory connection.
  • Page 4: Electrical Connections

    Installer’s Guide 9. The liquid line shut-off valve can now be opened. Remove 9. Mount the indoor thermostat in accordance with instruc- shut-off valve cap. Fully insert hex wrench into the stem tion included with the thermostat. Wire per appropriate and backout counterclockwise until valve stem just hook-up diagram (included in these instructions).
  • Page 5 Seacoast Salt Shields require the addition of BAYSEAC001 (Seacoast Kit) at installation time. Please refer to Applica- I. OPERATIONAL AND CHECKOUT tion Guide SS-APB006-EN: Trane - Seacoast Applications and PROCEDURES Seacoast Corrosion Protection Bulletin UN-SVB11A-EN. Final phases of this installation are the unit Operational and Checkout Procedures which are found in this instruction on page 8.
  • Page 6 Installer’s Guide 2TWB0012-036AA OUTLINE DRAWING Note: All dimensions are in MM (Inches). MODELS BASE FIG. 2TWB0012AA 651 (25-5/8) 724 (28-1/2) 651 (25-5/8) 5/8 1/4 127 (5) 57 (2-1/4) 181 (7-1/8) 44 (1-3/4) 457 (18) 2TWB0018AA 651 (25-5/8) 724 (28-1/2) 651 (25-5/8) 3/4 5/16...
  • Page 7: Mounting Hole Location

    Installer’s Guide MOUNTING HOLE LOCATION Note: All dimensions are in MM (Inches). NOTE: For model base size, see table on page 6. From Dwg. 21D152989 Rev. 0 18-BC52D5-5...
  • Page 8: Checkout Procedure

    S - Secondary Causes - 3 Phase Only Literature Order Number 01/10 File Number Supersedes Stocking Location Trane www.trane.com Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.