Flow-Paced Sampling, Two Bottles Per Sample - Teledyne Everywhereyoulook BLZZRD Installation And Operation Manual

Portable sampler
Table of Contents

Advertisement

BLZZRD Portable Refrigerated Sampler
Section 4 Standard Programming

Flow-Paced Sampling, Two Bottles Per Sample

This example shows you how to program the controller
to take flow-paced samples with the following settings:
The example displays are shown in the Normal
programming style.
• Program type: Standard
• Site description: Default
• Bottle kit: 14, 950 milliliter bottles
• Suction line length: 7 feet
• Pacing: Flow pacing, every two pulses
• Distribution: 2 bottles per sample
• Sample Volume: 250 milliliters
• Start time: Clock Time, 6:00
Wednesday, Friday
• Sampling duration: 24 hours
• Module: No module installed
1. At the Main Menu, select PROGRAM and press .
PROGRAM
VIEW REPORT
OTHER FUNCTIONS
2. The option NO will be blinking. Press .
SITE DESCRIPTION:
"FACTORY01"
CHANGE?
YES
3. Select the desired temperature units.
SELECT UNITS FOR
TEMPERATURE
°F
4. Select 14. Press .
NUMBER OF BOTTLES:
1
5. Type 950 and press .
BOTTLE VOLUME IS
950
ml
4-4
Example: Standard Program –
on Monday,
AM
RUN
NO
°C
4
14
(300-30000)
6. Type 7, then press .
SUCTION LINE LENGTH
IS
(3-99)
7. Select FLOW PACED, then, press .
TIME PACED
FLOW PACED
8. Enter the number of pulses between sample
events. Press .
FLOW BETWEEN
SAMPLE EVENTS:
2
PULSES (1-9999)
9. Select BOTTLES/SAMPLE.
SEQUENTIAL
BOTTLES/SAMPLE
SAMPLES/BOTTLE
10. Enter 2.
2
BOTTLES PER
SAMPLE EVENT (1-14)
11. For this example, select NO to disable the Run
Continuously option. Selecting YES allows the
program to run indefinitely by repeating the sample
distribution and assumes that filled bottles are
replaced at regular service intervals.
RUN CONTINUOUSLY?
YES
12. Type 250. Then, press .
SAMPLE VOLUME:
250
ml (10-1000)
7
ft
NO
Continued...

Advertisement

Table of Contents
loading

Table of Contents