Caution When Replacing Uniphier Ic (Xp Cpu) - Panasonic AG-HMC150P/AN Service Information

Table of Contents

Advertisement

10. Caution when replacing UniPhier IC (XP CPU)

When UniPhier IC (IC1200) on the Digital MAIN P.C.Board is exchanged, it is necessary to exchange NAND
FLASH (IP1500) at the same time. Please execute some operation according to the procedure for showing in the
following flow chart when you exchange UniPhier IC.
Exchange the UniPhier IC (IC1200) and NAND FLASH (IP1500)
Set the destination.
Regarding destination setting procedure, refer to item "6-3-1. Setting of destination" (page INF-24).
Write the Serial Number.
With Serial Number Writing Procedure, please consult service department of Professional AV Business unit.
Write the 1394 UID numbers.
Regarding UID writing procedure, refer to item "6-3-2. Write UID data" (page INF-25).
Set the Internal clock`s date and time.
Refer to item "Setting the calendar" of operation instructions or item "5-4-1. Setting and confirmation of
the Date and Time of the internal clock (SYSCON(S) section)" (page INF-18) and item "6-3-3. Setup of
Date and Time of internal clock" (page INF-26) for the setting method.
Execute the D-Terminal Output Level and Video Terminal Output Level Adjustment.
The adjustment procedure has been described to section 3 (Electrical adjustment procedure).
INF-47