Technical Data - Graco PrecisionFlo XL Instructions Manual

Hide thumbs Also See for PrecisionFlo XL:
Table of Contents

Advertisement

PrecisionFlo XL
*Minimum Flow Rates
. . . . . . . . . . . .
*Maximum Flow Rates
. . . . . . . . . . .
Maximum Fluid Working Pressure
Feed Pressure to Fluid Panel
With Electric Heated Hoses
At Regulator Outlet
Minimum Fluid Working Pressure
At Regulator Outlet
Minimum Back Pressure
Between Regulator Outlet
and Dispense Nozzle
Air Supply Pressure Range
Fluid Filtration Required
*Viscosity Range of Fluids
*Minimum Dispensed Shot Size
Wetted Parts
Meters and Fluid Panels
Power Requirements
. . . . . . . . . . . .
Power Supply Voltage Range
120 VAC nominal
. . . . . . . . . . . .
220 VAC nominal
. . . . . . . . . . . .
440 VAC nominal
. . . . . . . . . . . .
Operating Temperature Range
Controller
. . . . . . . . . . . . . . . . . . .
Fluid Panel
. . . . . . . . . . . . . . . . . .
Operating Humidity Range
* Flow rates and viscosities are general estimates. Flow rates drop as viscosity increases. Fluids are expected to
shear under pressure. New applications or fluids should always be tested to determine proper line sizes and
equipment selections.
See your Graco Authorized distributor for other capabilities
Polymitet is a registered trademark for Parker Seals.
r
PTFE

Technical Data

50 cc/minute with G3000 meter
100 cc/minute with SRZ 40 flow meter with 1/2" pneumatic or electric regulator
100 cc/minute with coriolis meter or mastic regulator
2000 cc/minute with G3000 meter
3000 cc/minute with SRZ 40 meter
4000 cc/minute with coriolis meter
. .
5000 psi (34.5 MPa, 345 bar)
. . .
3000 psi (21 MPa, 210 bar)
. . . . . . . . . .
3500 psi (24.0 MPa, 241 bar)
. . . . . . . . . .
500 psi (3.5 MPa, 34.5 bar)
. . . . . . . . .
500 psi (3.5 MPa, 34.5 bar)
. . . . . . .
60–120 psi (414–828 kPa, 4.1–8.3 bar)
Filtration required
. . . . . . . . . .
30 mesh (500 micron) minimum
. . . . . . . .
5000 to 50000 cps with G3000 meter
10000 to 500000 cps with SRZ 40 meter
2000 to 500000 cps with coriolis meter
. . .
10 cc with G3000 meter
25 cc with SRZ 40 meter
100 cc with coriolis meter
. . . . . .
303, 304, 17–4 stainless steel; tungsten carbide (with nickel binder),
Plated carbon steel, Polymitet
See page 19
85–164 VAC, 50–60 Hz., single phase
200–240 VAC, 50–60 Hz., single phase
400–480 VAC, 50–60 Hz., single phase
40_–122_ F (4_–50_ C)
40_–185_ F (4_–85_ C)
. . . . . . . .
0–90% non-condensing
Technical Data
r,
PTFE
309374
125

Advertisement

Table of Contents
loading

Table of Contents