10.4 Temperature cut-out
To protect against overheating, the tempera­
ture cut-out switches off the cordless mobile
dust extractor before it reaches the critical
temperature. The status display LED [1-12] in­
dicates a fault.
LED lights up red
► Switch off the cordless mobile dust extrac­
tor, let it cool down.
► Switch the cordless mobile dust extractor
on again after approx. ten minutes.
10.5 Connecting with the T-Loc
The cordless mobile dust extractor can be
closed, opened and connected by turning the T-
Loc:
Close the cordless mobile dust extrac­
tor [3a].
Open the cordless mobile dust extrac­
tor [3b].
Connect the cordless mobile dust extractor
to the storage box [3c].
Before lifting, always close the T-Loc at
the cordless mobile dust extractor or
connect to the storage box and check for secure
holding.
Max. load for connection to other Systainers: 20
kg
10.6 Use/Adjust shoulder strap [4]
Max. permissible load of shoulder strap: 20 kg
The shoulder strap can be attached in two dif­
ferent positions:
Carrying the cordless mobile dust extrac­
tor: Shoulder strap on the cordless mobile
dust extractor [4a]
Carrying the storage box with the cordless
mobile dust extractor: Shoulder strap on
the storage box [4b]
Before lifting, check the shoulder strap for
proper functionality and put the T-Loc on the
cordless mobile dust extractor into the corre­
sponding position.
Adjust the length of the shoulder strap at the
adjusting tab [4c].
24
Excessive temperature

11 Working

11.1 Extracting dry materials
CAUTION
Hazardous dust
Damage to the respiratory passage
► Always use a filter bag!
► Check that the main filter is undamaged
before extracting.
When extracting dust that exceeds the
limit value, only extract from one dust
source (power or compressed-air tool).
Observe the following when extracting dust
generated by operating power tools:
Ensure there is adequate ventilation! Observe
regional regulations!
Limit values: Exhaust air max. 50% of the fresh
air volume
Equation: Room volume V
L
W
Observe the following information:
Keep the area around the exhaust air open­
ing [1-8] clear.
The cordless mobile dust extractor is a sta­
tionary system and not suitable for pulling
at the suction hose. Use the handle [1-5],
front handle [1-7] or shoulder strap [4].
Two cleaning nozzles [5] are stored inside
the storage box.
11.2 After finishing work
► Switch off the cordless mobile dust extrac­
tor.
► Remove the battery pack.
Note: Keep the unused battery pack away
from metal objects (e.g. nails, screws, keys,
paper clips, etc.) as these may cause bridg­
ing of the contacts.
► Empty the dirt trap.
► Use the plug [6-2] to seal the suction open­
ing [6-1].
When commissioning the cordless mobile
dust extractor again, put the plug back into
the parked position.
► Place the suction hose [1-4] in the storage
box [1-2].
► Vacuum and wipe the inside and outside of
the cordless mobile dust extractor to clean
it.
x air renewal rate