21) C10∗∗~C14∗∗
• These malfunctions are concerned with faulty symptoms as they relate to software, hardware, and
communications. For remedial action change the board, check for cable connections, and turn OFF
and ON the power.
Code
C10∗∗
Reset the malfunction and turn OFF and ON the Power Switch.
C11∗∗
If the same malfunction is still detected, check cables for proper connection and, if
C12∗∗
they are okay, change PWB-B.
C12C∗
Run "Hard Disk Format" of "Image Memory" under "Function" available from the
Tech. Rep. mode.
If the same malfunction is still detected, change the Hard Disk Drive.
If the malfunction is again detected, change PWB-B.
C1300
Reset the malfunction and turn OFF and ON the Power Switch.
If the same malfunction is still detected, check the polygon driver, PWB-A, and con-
nector and, if they are okay, change either the polygon driver, PH Unit, or PWB-A.
C1326
Reset the malfunction and turn OFF and ON the Power Switch.
If the same malfunction is still detected, check PWB-B MJ1 for proper connection
and, if it is okay, change either PWB-B or PWB-A.
C1330
Reset the malfunction, turn OFF and ON the Power Switch, and unplug the power
C1334
cord and plug it in again.
If the malfunction is still detected, change PWB-A.
If the malfunction is again detected, run "I.R.
under "Function" available from the Tech. Rep. mode. If "NG" is shown, check the
harness between PWB-A, PWB-B, and PWB-IB and, if the harness is intact, change
the board.
C133B
Check cables for proper connection and, if they are okay, change the Finisher CPU
board.
C13F0
Reset the malfunction and turn OFF and ON the Power Switch.
C13F1
If the same malfunction is still detected, check the PWB-J connector and, if it is okay,
change either the PH Unit, PWB-J, or PWB-A.
C13F2
Check the Trailing Edge Stop and Edge Guide mechanism and harness and, if they are
C13F3
okay, change PWB-A or PWB-F.
C13F4
Reset the malfunction.
If the same malfunction is still detected, select "Adjust" → "Printer" → "Registration
(CD)" and make settings so that their total becomes less than 10.
If the same malfunction is still detected, replace the PH Unit.
C1401
Reset the malfunction (i.e., turn OFF and ON the Power Switch).
If the same malfunction is still detected, change PWB-IB.
C1402
Reset the malfunction (i.e., turn OFF and ON the Power Switch).
If the same malfunction is still detected, change PWB-IB.
C1410
Reset the malfunction (i.e., turn OFF and ON the Power Switch).
If the same malfunction is still detected, change PWB-IB.
C1426
Reset the malfunction.
If the same malfunction is still detected, change PWB-IB.
C1428
Reset the malfunction.
If the same malfunction is still detected, change PWB-IB.
C1429
Reset the malfunction.
If the same malfunction is still detected, change PWB-B.
If the malfunction is again detected, change PWB-IB.
C142A
Reset the malfunction.
If the same malfunction is still detected, change PWB-IB.
C1430
Reset the malfunction (i.e., turn OFF and ON the Power Switch).
If the same malfunction is still detected, change PWB-IB.
C143E
Action
→ ←
Mem.
∗See the relevant option service manual.
T-75
→ ←