MALFUNCTION

The copier CPU has a function that self-diagnoses the copier conditions. On detection of a malfunction,
the corresponding malfunction name, location, and definition codes are shown on the Touch Panel
together with a technical representative call message.
• Perform the following steps to reset malfunctions.
• Press the Trouble Reset Switch on Tech. Rep. Setting Switches Board PWB-S for the fusing mal-
functions (C05##).
• Turn OFF and ON the Power Switch for the following malfunctions:
C1401, C1402, C1410, C1430, C1461, C1462, C1468, C1469.
• Open and close the Lower Front Door for any other malfunctions.
<Malfunction Resetting Procedure>