3. Remove the screws (×2
unit.
4. Disconnect the connector (S2).
5. Remove the Power button.
6. Remove the screw (×1
7.20. Remove the K-Board
1. Remove the Cabinet assy. (See section 7.18.)
2. Remove the S-Board. (See section 7.19.)
3. Remove the screws (×7
4. Remove the Glass holder bottom rear.
5. Remove the screws (×4
6. Remove the Glass holder side (L, R).
7. Remove the screws (×9
8. Remove the Glass holder top rear and the Glass holder
top front.
9. Remove the Glass holder bottom front.
All manuals and user guides at all-guides.com
) and remove the S-Board
) and remove the S-Board.
).
).
).
10. Remove the screw (×1
11. Remove the claw (×1
12. Disconnect the connector (K1) and remove the K-Board
from LED Panel.
7.21. Replace the plasma panel
Caution:
A new plasma panel itself without Hanger metals is
fragile.
To avoid the damage to new plasma panel, carry a new
plasma panel taking hold of the Hanger metals after
assembling the Hanger metals and the Stand brackets.
1. Place a carton box packed a new plasma panel on the flat
surface of the work bench.
2. Open a box and without taking a new plasma panel;
Attach the C1-Board, C2-Board and the C3-Board, con-
nect the flexible cables from the plasma panel to the C1-
Board, C2-Board and the C3-Board, and fit the flexible
cable holders.
3. Attach the Hanger metals and the Stand brackets to the
new plasma panel.
4. Place the plasma panel on the servicing stand taking hold
of the Hanger metals.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
*When fitting the cabinet assy, be careful not to allow any
debris, dust or handling residue to remain between the
front glass and plasma panel.
22
).
).