Scope Of Delivery; Product Description; Type Plate - Bosch Stora WP 400 PK Installation And Service Instructions Manual

Dhw cylinder
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 29
2.4

Scope of delivery

400 and 500-litre cylinder
• Enamelled storage cylinder with PU rigid foam insulation
• Casing lid
• Magnesium anode
• Thermometer
• Technical documentation
• Foil jacket
• Flange cover
• Pack of adjustable feet
700-litre cylinder
• Enamelled storage cylinder
• Fibre insulation with PVC outer layer
• Floor insulation
• Head insulation
• Casing lid
• Magnesium anodes
• Thermometer
• Technical documentation
• Flange cover
• Pack of adjustable feet
2.5

Product description

Pos.
Description
1
Handhole
2
Magnesium anode (only with WP 700 P)
3
Rigid foam thermal insulation
4
Foil jacket
5
Sensor pocket for front cylinder temperature sensor
6
Thermometer
7
Magnesium anode
8
DHW outlet
9
DHW circulation connection at top
10
Cylinder flow
11
Sensor pocket for rear cylinder temperature sensor
12
DHW circulation connection
13
Cylinder return
14
Cold water inlet
Table 14 Product description (
Stora – 6721835341 (2021/04)
Fig. 2, page 57)
2.6

Type Plate

Pos.
Description
1
Type designation
2
Serial number
3
Nominal volume
4
Nominal volume of heat exchanger
5
Standby heat loss
6
Corrosion protection
7
Year of manufacture
8
Maximum DHW temperature, cylinder
9
Maximum flow temperature, heat source
10
Maximum flow temperature, solar side
11
Heating water heat input
12
Volumetric flow rate of heating water for heating water
input power
13
Maximum operating pressure on the domestic water side
14
Highest design pressure
15
Maximum operating pressure, heat source side
16
Maximum operating pressure, solar side
17
Maximum operating pressure on the domestic water side CH
18
Maximum test pressure on the domestic water side CH
Table 15 Type Plate
Product information
31

Advertisement

Table of Contents
loading

Table of Contents