No.
Error Code
24
E463
Over current trip / PFC over current error
25
E464
IPM Over Current(O.C)
26
E465
Comp. Over load error
27
E466
DC-Link voltage under/over error
Error due to abnormal rotation of the compressor or uncon-
28
E467
nected wire of compressor
29
E468
Error on current sensor (Short or Open)
30
E469
Error on DC-Link voltage sensor (Short or Open)
31
E470
Outdoor unit EEPROM Read/Write error (Option)
32
E471
Outdoor unit EEPROM Read/Write error (H/W)
33
E474
Error on IPM Heat Sink sensor of inverter 1 (Short or Open)
34
E475
Error on inverter fan 2
35
E483
H/W DC_Link Over Voltage Error
36
E484
PFC Overload (Over current) Error
37
E485
Error on input current sensor of inverter 1 (Short or Open)
38
E488
AC Input Voltage Sensor Error
39
E500
IPM over heat error on inverter 1
40
E554
Gas leak detected
Error due to mismatching capacity of indoor and outdoor
41
E556
unit
42
E557
DPM remote controller option error
43
E590
Inverter EEPROM CheckSum error
Samsung Electronics
All manuals and user guides at all-guides.com
Meaning
Remarks
Check OLP sensor
IPM
-
Check AC Power and DC Link Voltage
Check Comp wire
Check Outdoor Inverter PBA.
-
Check Outdoor EEPROM Data
Check Outdoor EEPROM PBA
Check Outdoor Inverter PBA.
FAN2 ERROR
Check AC Power
Check Outdoor Inverter PBA.
Check Outdoor Inverter PBA
Check Outdoor Inverter PBA.
Check the refrigerant
Check the indoor and Outdoor unit
Capacity
Check the indoor option code
-
4-23