Samsung AC036JB1DEC Service Manual page 57

Hide thumbs Also See for AC036JB1DEC:
Table of Contents

Advertisement

Option
SEG19
Individual control of
Explanation
PAGE
a remote controller
Indication Details Indication Details
0 or 1 Indoor 1
Indication
and
3
Details
If you input a number other than 0~4 on the individual control of the indoor unit(SEG 20), the indoor is set as
"Indoor 1".
Example) If you want to set as "Exterior temperature sensor : USE, External control : USE, Number of hours using filer :
2000hr", assign option codes except SEG 1, 7, 13, 19 which are page options.
SEG1
SEG2
0
SEG7
SEG8
1
SEG13
SEG14
2
SEG19
SEG20
3
1WAY/2WAY/4WAY MODEL : Drain pump(SEG8) will be set to 'USE + 3minute delay' even if the drain pump is set to 0.
1 WAY/2WAY/4WAY,DUCT MODEL : Number of hours using filter(SEG18) will be set to '1000hour' even if the SEG18 is set to
exept for 2 or 6.
4WAY MODEL : Even when the value of Heating setting compensation(SEG21) is set to '0' , it wil be recognized as '5°C' .
4-13
All manuals and user guides at all-guides.com
SEG20
SEG21
Heating setting
compensation
2
Indoor 2
0
Disuse
3
Indoor 3
1
2
4
Indoor 4
2
5
SEG3
2
-
SEG9
0
-
SEG15
1
0
SEG21
0
-
SEG22
SEG23
Motion detect
sensor
Indication Details
0.No Use (Factory Setting)
1. Standard Mode/Auto
Set OFF30 Min.
2. Standard Mode/Auto
Set OFF60 Min.
3. Standard Mode/Auto
Set OFF 120 Min.
RESERVED
4. Standard Mode/Auto
Set OFF 180 Min.
5. Premium Mode/Auto
Set OFF30 Min.
6. Premium Mode/Auto
Set OFF60 Min.
7. Premium Mode/Auto
Set OFF 120 Min.
8. Premium Mode/Auto
Set OFF 180 Min.
SEG4
SEG5
1
0
SEG10
SEG11
-
-
SEG16
SEG17
-
0
SEG22
SEG23
-
-
SEG24
RESERVED
SEG6
-
SEG12
0
SEG18
6
SEG24
-
Samsung Electronics