Connecting The Water Inlet Hose - LG DLEX89 0 Series Owner's Manual

Hide thumbs Also See for DLEX89 0 Series:
Table of Contents

Advertisement

2
Remove the terminal block access cover on
the upper back of the appliance.
3
Install UL-listed strain relief into the power
cord through-hole.
4
Thread the 3-wire, #10 AWG minimum copper
conductor power cable prepared in step 1
through the strain relief.
Terminal block
a
UL-listed strain relief
b
UL-listed 3-wire power cord
c
5
Attach the two hot leads (black and red) of the
power cord to the outer terminal block
screws.
6
Attach the neutral (white) wire to the center
terminal block screw.
7
Connect the external ground (if required by
local codes) to the green ground screw.
8
Tighten all screws securely.
9
Reinstall the terminal block access cover.
Hot lead (black and red)
a
1'' (2.5 cm)
Connecting the Water Inlet
Hose
To generate steam, the dryer must be connected
to the cold water tap using a new water supply
hose. Do not use old hoses.
• Do not overtighten the hoses or cross-thread the
• Do not reuse old hoses. Use only new hoses
• Periodically check the hoses for cracks, leaks,
• Do not stretch the water hoses intentionally, and
• Water supply pressure must be between 20 psi
• Do not store or install the appliance in a location
• Do not use flood-preventing hoses with auto
Neutral wire (white)
b
External ground wire (if required by local
c
codes)
Ground screw (green)
d
Wire from the appliance harness
e
WARNING
hose fittings. Overtightening or cross-threading
can damage the valves or couplings, resulting in
leaking and property damage.
when installing the appliance. Old hoses could
leak or burst causing flooding and property
damage. Contact an LG Customer Information
Center for assistance in buying hoses.
CAUTION
and wear, and replace the hoses every five years.
make sure that they are not pinched, crushed or
kinked by other objects.
and 120 psi (138 - 827 kPa). If the water supply
pressure is more than 120 psi, a pressure
reducing valve must be installed.
subject to freezing temperatures. Damage to the
water inlet hoses and internal mechanisms of
the appliance can result. If the appliance was
exposed to freezing temperatures prior to
installation, allow it to stand at room
temperature for several hours before use and
check for leaks prior to operation.
shut off devices. The devices can be tripped
during fill and prevent the appliance from filling
properly.
INSTALLATION
27