PCBs

3. PCBs
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
1
Remove the cover of
the electrical box.
2
Disconnect the
connectors [S52] and
[S102] from the service
monitor PCB.
3
Detach the 4 clamps
with pliers and remove
the service monitor
PCB.
4
Remove the screws of
the terminal board and
the earth/ground wire.
5
Unfasten the hook on
the right.
10
All manuals and user guides at all-guides.com
Procedure
Cover
[S52] [S102]
Service monitor PCB
Clamp
Earth/ground
wire
Terminal board
Points
Release the 4 hooks
indicated by ▼ .
(R9611)
[S52], [S102]: main PCB
(R16707)
(R16708)
Hook
(R23993)
Removal Procedure