Download Print this page

Sound Blankets - Daikin RKM33NV2S Service Manual

6.0/7.0/7.1/8.0/8.5/9.0 kw class 33000 btu/h class
Hide thumbs Also See for RKM33NV2S:

Advertisement

Si001272EC

6. Sound Blankets

Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
1
Open the sound blanket
(outer).
2
Remove the sound
blanket (top upper).
3
Remove the screw and
slightly push the
partition plate (1) to the
left for easy work.
4
Remove the sound
blanket (outer).
5
Remove the sound
blanket (inner).
Removal Procedure
All manuals and user guides at all-guides.com
Procedure
Sound blanket
Sound blanket
(top upper)
(outer)
Partition plate (1)
Sound blanket
(outer)
Sound blanket
(inner)
The sound blanket is fragile.
Pass the discharge pipe
through it carefully.
The design of the sound
blankets varies depending
on the model.
Since piping ports are torn
easily, remove the sound
blanket carefully.
(R18077)
(R18055)
The sound blanket is fragile.
Be careful of the notches of
the compressor mount (4
locations).
Compressor mount
(R23998)
Sound Blankets
Points
15

Hide quick links:

Advertisement

loading