8 • Completing Your Installation With or Without a Multi Staked Light Fixture (Cont.)
Uninstalling the Light Fixture
8-11. You must remove the wiring harness and its
components from the integrated light fixture. You
must then install the wiring harness into the
empty switch housing included with the fan.
8-12. Locate the reversing switch and carefully remove
the two screws holding the reversing switch to the
lower switch housing. Now, remove the reversing
switch from the housing.
8-13. Remove the patented breakaway connector from
the end of the fan pull chain. Carefully loosen the
bellmouth nut from the pull chain and remove the
pull chain switch from the light fixture housing.
8-14. Locate and carefully remove the two capacitors.
8-15. Unplug the two-wire connectors; one connector will have
a black with white striped wire and a white wire coming
from the multi-wire connector.
8-16. You have now disconnected the wiring harness and its
components and are ready to install them into the empty
switch housing. (The light switch remains in the light
assembly housing.)
8-17. Insert the pull chain and fan pull chain switch through the
round opening on the side of the empty switch housing.
Thread the bellmouth nut over the pull chain and hand
tighten the bellmouth nut.
8-18. Reattach the breakaway connector to the pull chain.
8-19. Insert the reversing switch into the square hole on the side
of the switch housing. Install and tighten the two screws
you removed previously from the other switch housing.
8-20. Carefully place the capacitors in the switch housing.
8-21. Continue with Step 8-6.
Speed
Switch
13
42679-01 • 01/15/09 • Hunter Fan Company
Steps 8-11 – 8-16
Reversing
Switch

Fan

Bellmouth Nuts
Steps 8-17 – 8-21
Switch
Housing
Fan
Speed
Switch
Light
Assembly
Housing
Capacitors
Light
Switch

Advertisement

Table of Contents
loading

This manual is also suitable for:

21187

Table of Contents