REPLACING THE FILTER

Through normal use, waterborne minerals and sediment become trapped in
the wick filter. The harder your water, the greater the amount of minerals in
the water, and the more often you will need to change your filter.
You will be able to monitor the life of the filter in your humidifier by
checking the Filter Check™ Indicator. When the unit is off, the
Filter Check™ Indicator will read in the OFF position. After 60 minutes
of use, Filter Check™ Indicator (refer to fig. 4 for close-up of indicator)
will move from the OFF position and
indicate your filter condition. A brand
new filter will register in the blue
section reading GOOD filter. After
frequent use of your humidifier, the
Filter Check™ Indicator will let you
know when the filter needs to be
changed.
When the needle is in the red (CHANGE) section, this means the proper
amount of moisture is not getting into your air due to the excessive minerals
and sediment that have become trapped on your filter. At this point, you
should replace your filter. It is important to change your filter as indicated to
obtain stated performance level.
To replace the filter, follow the steps below.
1. Be sure the humidifier is switched OFF and the unit is disconnected
from the electrical outlet.
2. Remove the tank and main housing to access the base tray.
3. Discard the old filter and follow weekly cleaning instructions.
4. Insert a new filter into the filter support in the base.
5. Replace the main housing and then the tank.
6. Repeat Operating Instruction steps.
It will take about 30 minutes for the humidifier to reach maximum output.
You can obtain a new filter by calling 1-800-5-HOLMES in the USA or by
visiting your nearest retailer or authorized service center. This humidifier
takes model HWF75 replacement filter.
Figure 3
A. CIRCULAR EXTENDED
LIFE FILTER
B. CIRCULAR FILTER
SUPPORT
C. FLOAT SWITCH
C
D. HUMIDIFIER BASE
D
R E P L A C I N G T H E F I L T E R
Figure 4
A
B

CLEANING AND MAINTENANCE INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry, heated indoor air.
To benefit most from the humidifier and avoid product misuse, follow all
instructions carefully. Please note that this is an electrical appliance and
requires attention when in use.
In addition, if you do not follow the recommended care and maintenance
guidelines, micro-organisms may be able to grow in the water within the
Water Tank. You must routinely follow the cleaning procedures that follow
in order to ensure proper, efficient operation of your humidifier. Proper
maintenance and cleaning is essential to the continued performance of
your unit and the avoidance of algae or bacteria build-up.

DAILY MAINTENANCE

1. Be sure the humidifier is switched OFF and the unit is disconnected from
the electrical outlet.
2. Remove the housing and the tanks from the humidifier and place them
in sink or tub.
3. Carry the base of the unit to the sink, remove the wick filter, place in sink,
drain any remaining water and rinse thoroughly to remove any sediment
or dirt. Wipe clean, and dry with a clean cloth or paper towel.
4. Drain the water from the tanks into the sink and rinse each tank
thoroughly. Wipe clean, and dry with a clean cloth or paper towel.
5. Put filter back in the filter supports, replace the housing, then refill the
tanks with cool tap water as instructed earlier in the Filling Instructions.
Do not overfill.
6. Follow Operating Instructions.

WEEKLY MAINTENANCE

To Remove Scale:
1. Repeat steps 1-4 above.
2. Partially fill the base with Holmes Cleanse Clean™ (Model S1710) as
instructed on bottle, or with two 8 oz. cups of undiluted white vinegar.
Leave this solution in the base for 20 minutes, while cleaning all interior
surfaces with a soft brush. Remove base scale by wiping the base with
a cloth dampened with undiluted white vinegar.
3. Rinse with clean warm water to remove the cleaning solution before
disinfecting the tank.
To Disinfect Humidifier Base Tanks:
1. Fill Humidifier Base with 2 gallons of water and 1 teaspoon of
chlorine bleach.
2. Fill each tank 1/2 full with water and 1 teaspoon of chlorine bleach.
3. Let the solution stand for 20 minutes, swishing every few minutes.
Wet all surfaces.
4. Carefully empty the Base and Tanks after 20 minutes, and rinse with
water until you cannot detect any bleach smell. Dry with a clean cloth
or paper towel.
5. Depending on the water hardness in your area, it may be necessary to
change the filter every 1-2 months. Re-insert the wick filter into the filter
support.
6. Refill the water tanks as directed with cool tap water, replace the
humidifier housing, and turn the Control Knob to ON.