Carrier AQUAZONE PCV015-060 Installation And Service Instructions Manual page 6

Compact high-efficiency water source heat pumps with puron refrigerant (r-410a)
Table of Contents

Advertisement

P
O
Q
AIR COIL AND FRONT SIDE
TOP VIEW-FRONT RETURN
P
O
Q
AIR COIL SIDE
TOP VIEW-RIGHT RETURN
S
R
U
T
C
CSP
FRONT
RIGHT RETURN RIGHT VIEW
- AIR COIL OPENING
OVERALL CABINET
50PCV
UNIT
SIZE
A
B
C
Width
Depth
Height
in.
21.5
21.5
39.0
015
cm
54.6
54.6
99.1
in.
21.5
21.5
39.0
018
cm
54.6
54.6
99.1
in.
21.5
21.5
40.0
024
cm
54.6
54.6
101.6
in.
21.5
21.5
40.0
030
cm
54.6
54.6
101.6
in.
21.5
26.0
45.0
036
cm
54.6
66.0
114.3
in.
21.5
26.0
45.0
042
cm
54.6
66.0
114.3
in.
24.0
32.5
46.0
048
cm
61.0
82.6
116.8
in.
24.0
32.5
46.0
060
cm
61.0
82.6
116.8
NOTES:
1. While clear access to all removable panels is not required, installer should take care to
comply with all building codes and allow adequate clearance for future field service.
2. Front and side access is preferred for service access. However, all components may be
serviced from the front access panel if side access is not available. (except on
50PCV009-030 and 041 sizes with front return).
3. Discharge flange is field installed.
3
4. Condensate is
/
in. (19.1 mm) IPT.
4
LEGEND
N
ASP — Alternate Service Panel
BSP — Blower Service Panel
CAP — Control Access Panel
CSP — Compressor Service Panel
HV
— High Voltage
IPT — Internal Pipe Thread
LV
— Low Voltage
a50-8413
N
P
N
AIR COIL SIDE
TOP VIEW-LEFT RETURN
U
AIR COIL
T
C
CSP
BACK
BACK
LEFT RETURN LEFT VIEW
- AIR COIL OPENING
50PCV015-060 UNITS
WATER CONNECTIONS
1
2
3
(IPT)
D
E
F
G
H
I
Loop In
Loop Out
1.9
1.4 13.8 1.4
8.1
1.4
4.8
3.6 35.1 3.6
20.6
3.6
1.9
1.4 12.9 1.4
8.1
1.4
4.8
3.6 32.8 3.6
20.6
3.6
1.9
1.4 13.8 1.4
8.1
1.4
4.8
3.6 35.1 3.6
20.6
3.6
1.9
1.4 15.2 1.4
8.1
1.4
4.8
3.6 38.6 3.6
20.6
3.6
1.9
1.4 15.7 1.4
8.1
1.4
4.8
3.6 39.9 3.6
20.6
3.6
1.9
1.4 16.6 1.4
8.1
1.4
4.8
3.6 42.0 3.6
20.6
3.6
1.9
1.4 16.6 1.4
8.1
1.4
4.8
3.6 42.2 3.6
20.6
3.6
1.9
1.4 16.7 1.4
8.1
1.4
4.8
3.6 42.4 3.6
20.6
3.6
Fig. 3 — 50PCV Unit Dimensions
STANDARD FILTER BRACKET
AIR COIL
B
O
A
M
S
R
AIR COIL
POWER SUPPLY
3/4" [19.1 MM] HV
KNOCKOUT
LOW VOLTAGE
1/2" [12.7 MM] LV
KNOCKOUT
LOW VOLTAGE
1/2" [12.7 MM] LV
KNOCKOUT
FRONT
ELECTRICAL KNOCKOUTS
J
K
L
1/2-in.
1/2-in.
3/4-in.
Size
(1.3 cm)
(1.3 cm)
(1.3 cm)
Low
Low
Power
Voltage
Voltage
Supply
1
/
4.1
7.1
10.1
2
1.3
10.5
18.1
25.7
1
/
4.1
7.1
10.1
2
1.3
10.5
18.1
25.7
3
/
4.1
7.1
10.1
4
1.9
10.5
18.1
25.7
3
/
4.1
7.1
10.1
4
1.9
10.5
18.1
25.7
3
/
4.1
7.1
10.1
4
1.9
10.5
18.1
25.7
3
/
4.1
7.1
10.1
4
1.9
10.5
18.1
25.7
1
4.1
7.1
10.1
2.5
10.5
18.1
25.7
1
4.1
7.1
10.1
2.5
10.5
18.1
25.7
6
ACCESS PANELS
FIELD INSTALLED
DISCHARGE FLANGE
BSP
ASP
CSP
CAP
ISOMETRIC
2 FT [610 MM]
SERVICE
VIEW
BSP
G
2
CAP
3
L
K
CSP
J
1
E
FRONT-VIEW
DISCHARGE CONNECTION
RETURN CONNECTION
DUCT FLANGE INSTALLED
(±0.10 in., ±2.5 mm)
O
P
M
N
Supply
Supply
Q
R
Width
Depth
6.4
3.8
14.0
14.0
5.3 2.3
16.1
9.5
35.6
35.6
13.6 5.8
6.4
3.8
14.0
14.0
5.3 2.3
16.1
9.5
35.6
35.6
13.6 5.8
6.4
3.8
14.0
14.0
5.3 2.3
16.1
9.5
35.6
35.6
13.6 5.8
6.4
3.8
14.0
14.0
5.3 2.3
16.1
9.5
35.6
35.6
13.6 5.8
6.4
3.8
14.0
14.0
5.1 2.3
16.1
9.5
35.6
35.6
13.1 5.8
6.4
3.8
14.0
14.0
5.1 2.3
16.1
9.5
35.6
35.6
13.1 5.8
6.9
7.3
16.0
18.0
5.1 2.3
17.4 18.4
40.6
45.7
13.1 5.8
6.9
7.3
16.0
18.0
5.1 2.3
17.4 18.4
40.6
45.7
13.1 5.8
AIRFLOW CONFIGURATION
Code
Return
F or H
Front
L or M
Left
G or R
Right
OPTIONAL
2 FT [610 MM]
SERVICE
ACCESS
LEFT RTN
(RIGHT RTN
OPPOSITE
SIDE)
1.00 [25.4 MM]
CONDENSATE
3/4" IPT
F
I
H
D
USING RETURN AIR
OPENING
S
T
Return
Return
U
Depth
Height
18.3
20.9
0.7
46.5
53.1
1.9
18.3
20.9
0.7
46.5
53.1
1.9
18.3
20.9
0.7
46.5
53.1
1.9
18.3
20.9
0.7
46.5
53.1
1.9
22.8
23.9
0.7
57.9
60.7
1.9
22.8
23.9
0.7
57.9
60.7
1.9
29.3
22.5
0.7
74.4
57.0
1.9
29.3
22.5
0.7
74.4
57.0
1.9
Discharge
Top
Top
Top

Hide quick links:

Advertisement

Table of Contents
loading