Toshiba PDR-M500 Service Manual page 26

Hide thumbs Also See for PDR-M500:

Advertisement

2.
Press the UP/DOWN button to select the item EVF. Then press the RIGHT button to enter EVF menu. Menu items
are shown as figure 3.4.3. Press the DISP button to initialize LCD setting.
Fig. 3.4.3
3.
Press the UP/DOWN button to select the item VCO. Press the RIGHT button, then adjustment screen will be
changed to EVF from LCD. If the image on EVF is NG, press MENU button at most 6 times to let it become
normal. If it doesn't work, the camera is NG.
Press the UP button until the upper image twists suddenly. Then press the OK button to set the upper limited value.
Press the DOWN button until the upper image twists again. Then press the OK button to set the lower limited value.
The center value of upper limit and lower limit will be saved and go back to EVF adjusting menu on LCD screen
automatically.
4.
Press the UP/DOWN button to select the item HPOS. Then press the RIGHT button to enter.
Then press the STROBE button and a white frame will be displayed on EVF as figure 3.4.4. Press the UP/DOWN
to adjust the frame of both left-hand side and right-hand side are clear. Then press OK button to return.
Fig. 3.4.4
5.
The setting range of Oscilloscope is AC, 500mV/div, 20us/div for the observation of the waveform of COM signal
(TP704). Press the UP/DOWN button to select the item COM A. Then press the RIGHT button. Then Press
UP/DOWN to set the COM signal waveform peak-peak to 3.5 +/- 0.18V shown as figure 3.4.5. Then press OK
button to return.
Fig. 3.4.5
6.
The setting range of Oscilloscope is AC, 500mV/div, 20us/div for the observation of the waveform of G signal
(TP702). Press the UP/DOWN button to select the item U_CNT. Then press the RIGHT button.
Then press UP/DOWN to set G signal shown as figure 3.4.6. The white level to black level peak-peak voltage
should be adjusted 2.3 +/- 0.12V. Then press OK button to return.
3.5Vp-p
24