EXALT FSB (Floor Standing Boiler)
HMI (Human Machine Interface) Removal
Kit Part Number
EXRKIT128
Each Kit Includes:
Display Module with cover
Recommended Tools:
Pozidriv Screwdriver
Flat Head Screwdriver
WARNING
!
Indicates a potentially hazardous situation
which, if ignored, can result in serious injury or
substantial property damage.
WARNING
!
For your safety, turn off electrical power supply
at service panel and allow unit to cool before pro-
ceeding to avoid possible electrical shock and
scald hazard. Failure to do so can cause severe
personal injury or death.
UIN 233226 A01
2021-52 Exalt FSB HMI Replacement
Revision Date: 02/2022
Description
HMI Replacement
NOTICE
Indicates special instructions on installation, operation
or maintenance, which are important to equipment
but not related to personal injury hazards.
WARNING
!
Failure to follow instructions below can result in
severe personal injury or damage if ignored.
Instructions are for a qualified installer/
service technician only.
Read all instructions before proceeding.
Follow instructions in proper order.
Model
EXALT Floor Standing
Models
1

Advertisement

loading

Summary of Contents for IDEAL EXALT FSB

  • Page 1 EXALT FSB (Floor Standing Boiler) HMI (Human Machine Interface) Removal Kit Part Number Description Model EXALT Floor Standing EXRKIT128 HMI Replacement Models Each Kit Includes: • Display Module with cover Recommended Tools: • Pozidriv Screwdriver • Flat Head Screwdriver NOTICE...
  • Page 2: Preliminary Instructions

    NOTICE Installing damaged equipment will cause malfunction of the 3. Press the OK button while the CH & DHW Settings boiler. Contact Ideal USA right away if the display module is icon is highlighted. damaged in any way. CH & DHW Settings 4.
  • Page 3 EXALT FSB (Floor Standing Boiler) HMI (Human Machine Interface) Removal 12. Press the RIGHT then DOWN buttons to highlight 6. Record all CH Settings in Table 1. Once completed, press the RIGHT button to highlight the Previous the Cascade icon, then press the OK button.
  • Page 4 EXALT FSB (Floor Standing Boiler) HMI (Human Machine Interface) Removal 3. Locate and undo the 2 M6 access screws. 4. Rotate the HMI Pod down. 1. Locate and undo the 2 M6 access screws 5. Remove the 4 M5 Pozidriv screws from the hinges.
  • Page 5 EXALT FSB (Floor Standing Boiler) HMI (Human Machine Interface) Removal 5. Fitting Wi-Fi Module on replacement HMI. WARNING 1. Connect to wire harness to the new HMI as shown Be careful when using the flat blade screwdriver. Do not in Figure 13.
  • Page 6: Boiler Settings

    EXALT FSB (Floor Standing Boiler) HMI (Human Machine Interface) Removal 7. Programming new Display Board 3. The required code is written on the data plate located at the side of the boiler. Use the code for 1. Follow the instructions in step 2 to gain access to the gas type, either Natural Gas or Propane.
  • Page 7: Maximum Setting

    EXALT FSB (Floor Standing Boiler) HMI (Human Machine Interface) Removal Table 1: Controls Settings HEATING SETTING FACTORY DEFAULT MINIMUM SETTING MAXIMUM SETTING EXISTING SETTING Heating Operation Enabled Demand Type Thermostat & Outd. Curve Absolute Max CH Setpoint 185°F [85°C] 68°F [20°C] 188°F [87°C] CH1 Maximum Setpoint 180°F [82°C]...
  • Page 8 EXALT FSB (Floor Standing Boiler) HMI (Human Machine Interface) Removal Table 1 Cont: BOILER SETTING FACTORY DEFAULT MINIMUM SETTING MAXIMUM SETTING EXISTING SETTING Lockout Temp. 210°F [99°C] Modbus Address 0=BCST 0=BCST Flex. Relay 1(CH) Flex. Relay 2(DHW) Flex. Relay 3(P3) CH1/CH2/DHW Flex. Relay 4(ERR) ERROR Flex.