Final Operations; Maintenance - Genius BLIZZARD 500 Translation Of The Original Instructions

Table of Contents

Advertisement

6. Move the gate to the open position by hand.
7. Position the opening magnetic limit switch (30) on the rack and
look for the point at which the corresponding N.C. contact opens.
8. Move the gate backwards and fasten the magnet to the rack using
the two screws provided (3 0-1).
9. Move the gate to the open position by hand and make sure that
the N.C. contact opens.

6.3 FINAL OPERATIONS

RISKS
PERSONAL PROTECTIVE EQUIPMENT
1. Ensure that the forces generated by the leaf are within the limits
allowed by the standard. Use an impact curve gauge in accord-
ance with standards EN 12453. For countries outside the EU,
when there is no specific local standard, the force must be less
than 150 N static.
2. Ensure that the maximum manual moving force of the leaf is less
than 225 N.
3. Use appropriate signs to highlight the areas where residual risks
remain despite having implemented all safety measures.
4. Put up the ''DANGER: AUTOMATIC MOVEMENT'' sign on the gate
in a visible position.
5. Put up the CE marking on the gate.
6. Complete the EC Declaration of Conformity of the machine and
the system Logbook.
7. Provide the owner/operator of the automation with the EC Decla-
ration, the system Logbook with the maintenance schedule and
the user instructions of the automation.
INSTALLING THE CASING
!
Mount the casing following the instructions in 31: choose between
the hexagonal insert screws and the Allen screws provided, size M5.

7. MAINTENANCE

RISKS
PERSONAL PROTECTIVE EQUIPMENT
F
Before performing any maintenance, disconnect the mains power
supply. If the disconnecting switch is not visible, apply a "ATTEN-
TION - Maintenance in progress" sign. Restore the power supply once
maintenance is complete and after tidying up the area.
!
Maintenance must be performed by the installer/maintenance techni-
cian.
Comply with all the safety instructions and recommendations provided
in this manual.
Close off the work site and prevent access/transit. Do not leave the
work site unattended.
BLIZZARD 500-900
8
The work area must be kept tidy and clear upon completing mainte-
nance.
Before starting activities, wait for the components subject to heating
to cool down.
Do not modify the original components in any way.
FAAC S.p.A. disclaims any liability for damage caused by components
that are modified or tampered with.
The warranty shall be forfeited in the event of tampering with com-
ponents.
For replacements, use only original spare parts GENIUS.