Connection of AC-DC Power Supply Unit PR-240
The power supply PR-240 is shipped ready for connection to a 200-230 VAC ship's mains.
If the ship's mains is 100 VAC – 115 VAC, change the tap connection and terminal board
connection as below. Attach label supplied as accessories to the punch mark in the front
panel according to the ship's mains.
Ship's mains
100-115 VAC
200-230 VAC
200-230 VAC
1
2
3
(a)
1
2
3
4
5
6
7
8
Top view of AC/DC power supply unit (cover removed)
Tap connection
SEL 115 V
SEL 230 V
White
Black
Punch mark
Terminal board connection
Terminal board
connection #1 & #2
b
a
100-115 VAC
White
1
Black
2
3
(b)
SEL
115 V
SEL
230 V
Tap connection (Pull out to disconnect)
2. CONNECTIONS
Front
Heat sink
2-5