1.8

Attachment Kit (option)

When using the retraction tank of FSV-243E/244E for FSV-247/248, the optional
attachment kit OP10-24 is necessary.
Name: Attachment kit Type: OP10-24 Code no.: 006-943-530
Name
Insulation gasket
Insulation gasket (2)
1. Clean the hull unit flange, the O-ring and O-ring groove. Coat them with a
slight amount of grease. Place the O-ring in position on the tank flange.
2. Lay the insulation gasket (1) on the top of the tank flange.
3. Orient the hull unit so that the bow mark (inscribed) on its flange points
toward the ship's bow. Note that heading adjustment in the display unit is
required if the bow mark does not face the ship's bow.
4. Confirm that the O-ring and the insulation gasket (1) are in position.
5. Place the hull unit on the tank.
6. Seven of the 24 bolt holes on the hull unit flange have already been fitted
with bolts (stern side). Insert the insulator gasket (2) into the bolt holes of the
tank flange to which these seven bolts are fitted.
7. Coat every bolt, washer and nut with a slight amount of grease to ease
removal. Fit the insulation gasket (2) into the bolt holes of the tank flange.
Fasten the hull unit to the retraction tank with insulation gasket (2), flat
washers, spring washers and hex bolts.
8. Reinforce the hull unit against vibration by extending stays to the ship's hull
from the two eye bolts at the top of the hull unit, referring to the figure at the
top of page 1-7.
Type
MS-1000-67
MS-1000-68
Code No.
Qty
000-857-220
24
000-857-221
24
1-19