Furuno CH-37 Installation Manual page 17

Color sector scanning sonar
Hide thumbs Also See for CH-37:
Table of Contents

Advertisement

Figure 1-10 Passing pipe clamp, gasket, flat washer and cable gland on main shaft
9. Fasten the hull unit to the transducer tank, orienting it so the ship's fore-aft
line crosses the front panel of the raise/lower drive block at an angle of ap-
proximately 45 degrees.
M20 F.W.
M20 S.W.
M20 Nut
CAUTION:
1. Do not drag hull unit on floor.
2. Do not rest hull unit against wall.
Figure 1-11 Fastening the hull unit to the transducer tank
Hold here with
70
pipe wrench.
3
Tighten cable gland for
gap of approx. 3 mm.
M20 x 90 (8 pcs)
M20 Flat washer
Outer edges of main body
flange and tank should be
in line with one another.
Wipe off foreign material.
Apply Kinoruster.
Inscribe bow mark,
referring to the bow mark
on the soundome.
Pipe clamp
For 2.2 m, 3.8 m shaft
Orient the hull unit as above
to minimize shock and vibration
on the raise/lower drive block
when ship is pitching and
rolling.
1-7
Gasket
Cable gland
Flat washer
Pipe cap
45
BOW