Talk 2-8 Emergency Alarm; Technical Precautions; Troubleshooting - Aiphone GT-1A Operation Manual

Residential/tenant station
Hide thumbs Also See for GT-1A:

Advertisement

2-8
Emergency alarm
1
When the emergency alarm switch is pressed and locked (or
when there is a line-off activation), an alarm will sound from the
residential/tenant station, and a warning signal will be sent to the
guard station.
Emergency
alarm switch
2
When there is a call from the guard station, the alarm sound will
change to a call tone.
• The Tone off LED will flash.
3

TECHNICAL PRECAUTIONS

• Cleaning:
Clean the unit with a soft cloth dampened with a neutral household
cleanser. Do not use any abrasive cleaner or cloth.
CAUTION: Do not use chemicals such as thinner or benzine. In
addition, do not use a scrub brush, sandpaper, etc. Otherwise the
unit surface could be damaged or discolored.
4

TROUBLESHOOTING

If the unit fails to operate normally, check the following points to determine whether the fault can be corrected by the simple measures suggested.
If it cannot be corrected, or the fault is not listed in the "Symptom" column, contact your administrator or the system supplier.
Symptom
The call tone from the entrance station or the
door station/doorbell does not sound.
Nothing is heard even if the TALK button is
pressed.
There is no response even if the guard station
call/light button is pressed.
Communication is interrupted, or it becomes a
one-way conversation.
The station does not work at all.
The Tone off LED is flashing during standby.
Guard station
Call
The call tone volume is set to "OFF".
The speaker volume switch is set to "LOW".
A guard station is not installed.
Loud sounds around this station, entrance station, or
door station.
The power of the system may be off.
The Tone off LED flashes at approximately 4 second
intervals when the call tone volume switch is set to
"OFF".
Doctor call is enabled.
* Available depending on the equipment used in the system.
3
Press the TALK button to communicate with the guard station.
The emergency alarm will sound again when communication has
finished.
• The Tone off LED will turn on.
• It will turn off if the TALK button is pressed again.
4
Release the lock position of the emergency alarm switch to return
to standby (restore the system to normal status), then the alarm
will stop.
NOTES: 1. On the residential/tenant station, the emergency alarm and
call tone will be emitted at a loud (HIGH) volume, regardless
of the volume setting.
2. The emergency alarm function can be activated even when the
system is in use. (Alarms can be activated at the same time by
up to 5 units.)
3. Residential/tenant stations within the same residence will be
unable to receive normal calls or doorbell calls while the
emergency alarm is sounding. It is only possible to respond to
calls from the guard station.
4. During the emergency alarm, the entrance station cannot
make calls to the residential/tenant station or to the guard
station that are producing emergency alarms.
• If there is a system malfunction, contact a qualified technician for
service.
Cause
Adjust the call tone volume.
Adjust the speaker volume switch during
communication.
Contact your administrator.
Because of auto-voice actuation, audio may be
interrupted when a surrounding sound is loud. In that
case, press and hold the TALK button to enable the
push-to-talk function.
Contact your administrator.
Change the call tone volume level.
Disable the doctor call function.
- 5 -