12 Measurements and Adjustments

This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in
Troubleshooting Guide (P.31)

12.1. Equipment Required

• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
Hewlett Packard, 53131A is recommended.
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
This equipment may be useful in order to precisely adjust like a mass production.

12.2. The Setting Method of JIG

<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PNZZTGF350M (for KX-
TGF35x), PNZZTGF380M (for KX-TGF38x),

12.2.1. Connections (Base Unit)

Connect the AC adaptor.
Connect the JIG Cable GND (black).
Connect the JIG Cable RX (red) and TX (yellow).
AC adaptor
To Serial Port
(COM port 1*)
PC
Note:
*: COM port names may vary depending on what your PC calls it.
KX-TGF350N/KX-TGF352N/KX-TGF353N/KX-TG572SK/KX-TGF380M/KX-TGF382M/KX-TGF383M/KX-TGFA30N/KX-TGFA30M
DC JACK
1
JIG Cable
3
URX (red)
2
GND (black)
3
UTX (yellow)
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E),
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
Resistor
R2
R3
R4
R7
57
change
the
following
Old value (k)
New value (k)
22
3.3
22
3.3
22
4.7
4.7
10
Base unit P. C. board
values