2. BMC image[Primary version:2.20, backup version:1.22]
3. BIOS image[Booted version: 3.41.0.9-19]
4. CPLD image[CPLD version: 0x10]
9. Reset BMC after CPLD update completion and system bootup
q. Exit
Enter your choice:q
~/Downloads/temp
root@ubs18-04:~/Downloads#
5. After firmware upgrade completes, enter q to exit.
6. Once all firmware updates are complete, a system power cycle is required either with remote power cycler or manually
unplugging and plugging back the power cord.
NOTE:
The power down state should be a minimum of fifteen seconds for the complete power drain.
NOTE:
UFW has been tested for use with Ubuntu 18.04 and CentOS/RHEL 7.x.
NOTE:
If an IPMI session error is seen while connecting to the BMC, run following command to reset the BMC prior to
re-run of UFW. root@ubs18-04:~/# ipmitool -I lanplus -H xxx.xx.xx.xxx -U admin -P admin mc reset cold
NOTE:
UFW has a limitation that rNDC and x722 firmware upgrade cannot be done through the BMC network.
Firmware upgrade options available for this hardware via DIAG OS and firmware workaround sections.