2. Other related items
A. Counter clear
Maintenance cycle setting
Jam/trouble counter clear
Paper feed counter clear
Scan/Stapler/Stamp counter clear
Maintenance counter clear
Copy counter clear
Printer/other counter clear
FAX counter clear
Scanner mode counter clear
*: When maintenance message is displayed, replace consumption part reaching the number of sheets of maintenance, then clear the replaced
part's counter only.
3. Display of maintenance execution timing
The message of maintenance execution timing is displayed when each counter reaches the set value. The relations between the messages
and the counters are shown below.
A. Maintenance counter
Display content
-
Maintenance required. Code: TA
Maintenance required. Code: TA
* After execution of maintenance, be sure to execute SIM24-4 to clear the maintenance counter (Total).
B. Transfer unit
Display content
Maintenance required.: TK
* After execution of the maintenance, execute SIM24-4 to clear the transfer unit print counter, the accumulated number of rotations counter
and the use day counter.
C. Fusing unit
Display content
Maintenance required.: FK1
Maintenance required.: FK2
* After execution of the maintenance, execute SIM24-4 to clear the fusing heat roller print counter, the accumulated rotation number counter
and the use day counter.
D. OPC drum
Display content
Maintenance required.: DK
Maintenance required.: DK
* Judgment is made at the earlier timing of the drum print counter or the drum rotations accumulated number counter.
E. Developer
Display content
Maintenance required.: VK
Maintenance required.: VK
* Judgment is made at the earlier timing of the developer print counter or the developer accumulated rotation number counter.
The developer rotation number is synchronized with the drum motor rotation number.
Item
SIM26-38-A
set value
0 (Print continue)
Maintenance counter (Total)
1 (Print stop)
0 (Print continue)
1 (Print stop)
Counter name
Transfer unit print counter
Counter name
Fusing heat roller print counter
Pressure roller print counter
Counter name
OPC drum print counter
OPC drum accumulated rotation number counter
Counter name
Developer print counter
Developer accumulated rotation number counter
MX-M316N MAINTENANCE 9 – 4
SIM
SIM 21-1
SIM 24-1
SIM 24-2
SIM 24-3
SIM 24-4
SIM 24-6
SIM 24-9
SIM 24-10
SIM 24-15
Display condition
Counter name
When 90% of the SIM21-1 set
value is reached.
When the SIM21-1 set value is
reached.
Display condition
150K
Display condition
150K
300K
Display condition
100K
550K rotations
Display condition
100K
550K rotations
Remarks
*
Print JOB Enable/
Counter value
Print JOB Enable/
Counter value
Print JOB Enable/
Counter value
Print JOB Enable/
Counter value
Print JOB
Enable/Disable
Counter value
Disable
-
Enable
Enable
Disable
Disable
Enable
Disable
Enable
Disable
Enable
Enable