Power Amplifier Adjustment / パワーアンプ調整 - Yamaha RX-V573 Service Manual

Hide thumbs Also See for RX-V573:
Table of Contents

Advertisement

■ POWER AMPLIFIER ADJUSTMENT / パワーアンプ調整
1. Right after power is turned on, confirm that the voltage
across the terminals of R2154 (SURROUND BACK Rch),
R2152 (SURROUND Rch), R2149 (FRONT Rch), R2151
(CENTER), R2150 (FRONT Lch), R2153 (SURROUND
Lch) and R2155 (SURROUND BACK Lch) are within the
confines of 0.1 mV to 10 mV.
2. If measured voltage exceeds 10 mV, remove R2108
(SURROUND BACK Rch), R2107 (SURROUND
Rch), R2111 (FRONT Rch), R2110 (CENTER), R2109
(FRONT Lch), R2112 (SURROUND Lch) and R2133
(SURROUND BACK Lch), and then reconfirm the
voltage.
Attention
If the measured voltage exceeds 10 mV after repairing
the power amplifier, check other parts again for any
possible defect before removing the resistor.
3. Confirm that the voltage is within the confines of 0.2
mV to 15 mV after 60 minutes.
0.1 mV – 10 mV
(DC)
R2110
R2151
MAIN (1) P.C.B.
R2154 (SURROUND BACK Rch)
R2152 (SURROUND Rch)
R2149 (FRONT Rch)
R2151 (CENTER)
R2150 (FRONT Lch)
R2153 (SURROUND Lch)
R2155 (SURROUND BACK Lch)
Front side
R2109
R2111
R2108
R2150
R2149
R2154
1.  電源投入直後、R2154  (SURROUND BACK Rch) 、R2152
(SURROUND Rch) 、R2149 (FRONT Rch) 、R2151
(CENTER) 、R2150 (FRONT Lch) 、R2153 (SURROUND 
Lch) 、R2155  (SURROUND BACK Lch)の端子間電圧を
測定し、0.1 mV から 10 mV の間であることを確認して く
ださい。
2.  電圧が 10 mV を超えている場合は、 R2108  (SURROUND 
BACK  Rch) 、R2107 (SURROUND  Rch) 、R2111  (FRONT 
Rch) 、R2110 (CENTER) 、R2109 (FRONT  Lch) 、R2112
(SURROUND  Lch) 、R2113  (SURROUND  BACK  Lch)を
外し、電圧を再確認して ください。
注意
パワーアンプ修理後に 10  mV を超えている場合は、抵
抗を外す前に故障箇所を調べて ください。
3.  60 分後、電圧が 0.2 mV 〜 15 mV であることを確認して
ください。
R2113
R2107
R2112
R2155
R2152
R2153
RX-V573/HTR-5065