Dimplex BF8000ST Owner's Manual page 13

Electric fireplace
Hide thumbs Also See for BF8000ST:
Table of Contents

Advertisement

!
IMPORTANT: Only handle the Log Set by the Ember bed.
!
NOTE: Log Set fits tightly into firebox, some force may be
necessary to remove.
7. Set Log Set in front of fireplace.
8. Remove flicker rod by sliding flicker rod to the left away from the
flicker motor and lifting out.
9. Remove light bracket for easier access to light bulbs.
10. U nscrew bulbs counter clockwise.
11. Insert new bulbs.
12. R eplace the Log Set by inserting the front edge of the fireplace and
push down on the rear edge of the Ember bed until it snaps into
place (Figure 8).
13. L ay unit on it's back and slide front glass back into position and
attach trim.
!
NOTE: Ensure the Log Set is installed tightly under the back ledge
to prevent light leakage.
Upper Light Bulb Requirements
Quantity of two (2) clear chandelier or candelabra bulbs with an E-12
(small) socket base, 15 Watt rating.
Do not exceed 25 Watts per bulb.
To access the upper light bulb area:
1. Slide fireplace out of mantel.
2. Lay unit on it's back for safe removal of Front Glass.
3. Remove four (4) Phillips screws from right side of Trim.
4. Remove Trim.
5. Slide glass to the right side of the fireplace to remove (Figure 7).
6. Upper bulbs are located in the upper left and upper right corners of
fireplace.
7. Unscrew bulbs counter clockwise.
8. Insert new bulbs.
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents