Connecting Fireplace To Gas Supply - Desa CGF280PT Owner's Operation And Installation Manual

Desa owner's operation and installation manual unvented (vent-free) propane/lp gas fireplace cgf265pva, cgf280pt
Table of Contents

Advertisement

INSTALLING
Continued
102665
Approved
Flexible
Gas Line
* Purchase the optional A.G.A. design-certified manual shutoff valve from your
dealer. See Accessories, page 38.

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to LP gas, not provided)
1. Remove fireplace screen. Remove two screws that hold fireplace screen in
place for shipping. These screws are located near top of screen. Discard screws.
Lift fireplace screen up and pull out to remove.
2. Remove access door from rear or side of fireplace. See Product Identification,
page 4, for access door locations.
3. Remove screws that attach log base assembly to fireplace. Carefully lift up log
base assembly and remove from fireplace (see Figure 18).
Do not pick up log base assembly by burners. This could damage
burners. Only handle base by grates.
Figure 18 - Removing Log Base Assembly From Fireplace
A.G.A. Design-Certified Manual Shutoff Valve
With 1/8" NPT Tap*
3" Minimum
Figure 17 - Gas Connection
CAUTION
WARNING ICON
G 001
From External Regulator
(11" W.C. to 14" W.C.
Pressure)
Sediment
Trap
Tee Joint
Pipe Nipple
Cap
Continued