Faults
E:18 or indication for water
supply is lit.
E:22 is on.
1
E:24 lit.
E:25 lit.
1
Depending on the device version
Cause
Strainer at water inlet is
clogged.
Strainers are dirty or clogged.
Drain hose is clogged or
kinked.
Siphon connection is still closed.
Drain pump cover is
loose.
Drain pump is blocked.
Drain pump cover is
loose
Troubleshooting NL
Solution
The amount of water flowing
in when the tap is open is at
least 10 l/min.
Switch off the device.
1.
Remove the plug from the socket.
2.
Turn off the tap.
3.
Unscrew the water connection.
4.
Remove the strainer from the inlet hose
5.
Clean the strainer.
6.
Place the strainer in the supply hose.
7.
Screw on the water connection.
8.
Check the water connection for
9.
leaks.
Put the plug back in the
10.
socket.
Switch on the device.
11.
Clean the sieves.
"Cleaning Sieves", Page 42
Route the drain hose without
1.
kinks.
Remove the remains.
2.
Check the connection to the
fon and open it if necessary.
Remove the cover of the drain
pump → Page 56 well fixed.
Clean the drain pump.
"Clean the drain pump",
Page 56
Remove the cover of the drain
pump → Page 56 well fixed.
45