Physical Data - Carrier 48AK Installation, Start-Up And Service Instructions Manual

Single package rooftop units electric cooling/gas heating, with reciprocating compressor
Table of Contents

Advertisement

UNIT 48AJ,AK,AW,AY
NOMINAL CAPACITY (tons)
BASE UNIT OPERATING WEIGHT (lb)
COMPRESSOR
Quantity...Type (Ckt 1 , Ckt 2)
Number of Refrigerant Circuits
Oil (oz) (Ckt 1 , Ckt 2)
REFRIGERANT TYPE
Operating Charge (lb-oz)
Circuit 1
Circuit 2
CONDENSER COIL *
Quantity
Rows...Fins/in.
Total Face Area (sq ft)
CONDENSER FAN
Nominal Cfm
Quantity...Diameter (in.)
Motor Hp
EVAPORATOR COIL
Tube Size (in.)
Rows...Fins/in.
Total Face Area (sq ft)
EVAPORATOR FAN
Quantity...Size (in.)
Type Drive
Nominal Cfm
Motor Hp
Motor Frame Size
Motor Bearing Type
Maximum Allowable Rpm
Motor Pulley Pitch Diameter
Nominal Motor Shaft Diameter (in.)
Fan Pulley Pitch Diameter (in.)
Nominal Fan Shaft Diameter (in.)
Belt Quantity
Belt Type
Belt Length (in.)
Pulley Center Line Distance (in.)
Factory Speed Setting (rpm)
FURNACE SECTION
Rollout Switch Cutout
Temp (F) †
Burner Orifice Diameter (in. ...drill size)
Natural Gas
Std
Liquid Propane
Alt
Thermostat Heat Anticipator Setting
Stage 1 (amps)
Stage 2 (amps)
Gas Input (Btuh)
Stage 1
Stage 2
Efficiency (Steady State) (%)
Temperature Rise Range
Manifold Pressure
(in. wg)
Natural Gas
Std
Liquid Propane
Alt
Gas Valve Quantity
HIGH-PRESSURE SWITCH (psig)
Cutout
Reset (Auto.)
LOW-PRESSURE SWITCH (psig)
Cutout
Reset (Auto.)
RETURN-AIR FILTERS
Quantity...Size (in.)
OUTDOOR AIR FILTERS
Quantity...Size (in.)
LEGEND
Al
— Aluminum
Bhp — Brake Horsepower
Cu
— Copper
Table 1A — Physical Data — 48AJ,AK,AW,AY Units
020D/E
20
1...06D328, 1...06D818
2
115, 88
25-0
31-0
Cross-Hatched
3
/
8
1
4...15
33.3
13,420
2...30
1
3
/
8
4...15
31.7
2...20 X 15
Belt
8,000
5
10
15
7.5
184T
215T
254T
213T
Ball
1200
4.9
4.4
5.7
5.4
1
1
/
1
3
/
1
3
/
1
3
8
8
8
12.4
8.6
9.1
12.4
15
1
/
16
1
2
2
1
BX56
BX50
5VX530
BX56
56
63
53
56
16.0-18.7
15.6-18.4
15.0-17.9
15.6-18.4
717
924
1096
773
225
.111...34
.089...43
0.1
0.1
262,500/394,000
350,000/525,000
82
15-45/35-65
3.5
3.5
2
426
320
27
67
10...20 x 24 x 2
8...16 x 25
4...20 x 25
025D/E
25
See Operating Weights Table 2.
2...06D328
2
115 ea.
R-22
25-0
25-0
" Copper Tubes, Aluminum Lanced, Aluminum Pre-Coated, or Copper Plate Fins
1
4...15
33.3
Propeller Type
13,420
2...30
1
Cross-Hatched Copper Tubes, Aluminum Plate Fins
3
/
8
4...15
31.7
Centrifugal Type
2... 20 X 15
Belt
10,000
10
15
10
215T
254T
215T
Ball
1200
6.1
5.5
4.4
/
1
3
/
1
5
/
1
3
/
8
8
8
8
11.1
8.7
9.4
15
1
/
16
1
2
2
5VX590
5VX570
BX50
59
57
50
15.6-18.4
15.0-17.9
15.6-18.4
962
1106
848
225
.111...34
.089...43
0.1
0.1
262,500/394,000
262,500/394,000
350,000/525,000
350,000/525,000
82
15-45/35-65
3.5
3.5
2
426
320
27
67
10...20 x 24 x 2
8...16 x 25
4...20 x 25
*Sizes 020-030: Circuit 1 uses the lower portion of condenser coil, Circuit 2 uses the upper
portion.
Sizes 035-050: Circuit 1 uses the left condenser coil, Circuit 2 the right. All units have
intertwined evaporator coils.
†Rollout switch is manual reset.
NOTE: High heat is for 48AJ,AW only.
21
027D/E
030D/E
27
2...06D328
1...06D537, 1...06D328
2
115 ea.
115 ea.
29-0
28-0
1
4...15
33.3
13,420
2...30
1
3
/
8
4...15
34.7
2... 20 X 15
2... 20 X 15
Belt
11,000
15
20
10
254T
256T
215T
Ball
1200
4.9
5.9
4.4
1
5
/
1
5
/
1
3
/
8
8
8
8.1
8.7
9.0
15
1
/
16
2
2
2
5VX500
5VX530
BX50
5VX530
50
53
50
15.0-17.9
15.0-17.9
15.6-18.4
15.0-17.9
1059
1187
884
225
.111...34
.111...34
.089...43
.089...43
0.1
0.1
262,500/394,000
350,000/525,000
82
15-45/35-65
15-45/35-65
3.5
3.5
2
426
320
27
67
10...20 x 24 x 2
10...20 x 24 x 2
8...16 x 25
8...16 x 25
4..20 x 25
4...20 x 25
30
2
27-0
29-0
1
4...15
33.3
13,420
2...30
1
3
/
8
4... 5
34.7
Belt
12,000
15
20
254T
256T
Ball
1200
5.7
5.9
1
5
/
1
5
/
8
8
9.1
8.7
15
1
/
16
2
2
5VX530
53
53
15.0-17.9
1096
1187
225
0.1
0.1
82
3.5
3.5
2
426
320
27
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents