Carrier 42D Series Installation, Start-Up And Service Instructions Manual page 35

Fan coil air conditioners
Table of Contents

Advertisement

LEGEND
CR — Cold Water Return
CS — Cold Water Supply
D — Drain
HR — Hot Water Return
HS — Hot Water Supply
R — Return
S — Supply
ITEM
DESCRIPTION
1
Electrical Knockouts
2
Strip Heater** (Optional)
3
Limit Switch**†† (Optional)
1
4
/
-in. Isolation Ball Valves**
2
5
Coil Stub Outs
6
Shipping Brace
7
Flexible Drain Tube/P-Trap
1
8
Coil
/
-in. OD Copper Tube
2
9
Filter, Throwaway, 1-in.**
10
Return Air Opening
11
Air Vent, Manual
12
Knockout (For Optional Remote Mounting)
13
Molex Connector for Field-Installed Stat
14
Control Box
15
Drain Pan
16
Return Air Blockoff Panel (Optional)
17
Blower
18
Motor, 3-Speed, PSC, with Quick Connect
19
Access Panel (Control Box)
20
Control Opening (Surface Mount Thermostat)
1
21
Duct Collar,
/
-in. Extension (Typical)
2
22
Supply Air Opening(s)
**Factory-Installed.
††Field-Installed.
*Drawing provided for reference only. Dimensions may vary with options ordered.
QTY
NOTES:
1. Units are fabricated of 18-gage galvanized steel with a 16-gage galvanized fan deck.
1
2. All risers are insulated with
1
3. Thermostats shipped loose for field connection.
1
4. Risers are piped to coil with valves as specified.
5. Blower, motor, valves, coil, and filter are accessible through the return air opening.
2/4
6. Unit and control box are insulated with
2/4
7. Riser length = [(floor to floor) +2 in.], maximum riser length = 115 inches.
8. Maximum riser size is 2
2/4
9. Expansion loops in hot water heating circuits as required.
1
1
10. A 9-in. x 2
/
-in. slot is provided in the inside back panel for coil connection penetration to permit expansion
4
and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot.
1
11. Drawing is pictorial (see unit arrangements for actual supply and return air orientation).
1
12. All dimensions are in inches.
1
1
NOM
UNIT
2
AIRFLOW
Single Supply
SIZE
(cfm)
1
1
03
300
1
04
400
1
06
600
1
08
800
1
1
10
1000
1
12
1200
1/2/3
†Unit weights are based on dry coils and minimum rows. Weights exclude packaging, valves, and other components.
1/2/3
Fig. 32 — 42SGS Furred-In Slave Stack Dimensions
1
/
-in. closed cell insulation.
2
1
/
-in. coated fiberglass insulation.
2
1
/
-in. diameter. If larger sizes are required, please consult the factory.
2
DIMENSIONS (in.)
Double Supply
Top Supply
A
B
A
B
C
14
8
14
6
14
14
12
14
6
14
18
10
18
6
16
18
12
18
6
16
22
8
18
22
8
18
35
A42-4129
E
G
H
I
D
1
1
10
17
1
/
1
/
14
2
2
1
1
10
17
1
/
1
/
14
2
2
12
20
1
2
18
12
20
1
2
18
16
24
1
3
22
16
24
1
3
22
UNIT
WEIGHT†
(lb)
162
203
216
234
252
275