The Burnham EC50 00 Control includes a water temperature sensor. Mount this sensor to the
sys te m s upply piping.
8. Burnham EC5000 Circulator Zoned System – Refer
to Figure 19 of this manual for the electrical
diagram for this type of system. Wire the system as
indicated in that diagram. Refer to the manual
provided with the Burnham EC5000 Control for
control operation and setup details.
NOTICE
9. Burnham EC5000 Zone Valve Zoned System –
Refer to Figure 20 of this manual for the electrical
diagram for this type of system. Wire the system as
indicated in that diagram. Refer to the manual
provided with the Burnham EC5000 for control
operation and setup details.