INITIAL SET-UP
1.
Locate the drip tray assembly beneath the dispenser nested in the packing material.
2.
Remove the drip tray and the drip tray cover and set them aside.
3.
Remove the water strainer assembly from the drip tray and set it aside.
4.
Remove the four legs from the drip tray, apply non-skid pads to the bottom of the legs and securely install
the legs in the dispenser base.
ELECTRICAL REQUIREMENTS
CAUTION - The dispenser must be disconnected from the power source until specified in Initial Set-Up.
The 120 volt version of this dispenser has an attached cordset. The mating connector must be a NEMA 5-15R.
WHITE
NEUTRAL
L1BLACK
Requires 2-wire grounded ser-
vice rated 120 volts ac, 15 amp,
single phase, 60 Hz
ELECTRICAL HOOK-UP
-
CAUTION
Improper electrical installation will damage electronic components.
1.
An electrician must provide electrical service as specified.
2.
Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.
3.
Open the front door of the dispenser and place the heater switch in the "OFF" (upper position).
4.
Remove the right side panel of the dispenser.
120 volt versions proceed to step 6.
120/240 volt and 240 volt versions proceed to next step.
5.
Install the electrical wiring to the terminal block as illustrated above.
6.
Connect the dispenser to the power source and verify the voltage at the terminal block. Reinstall the side
panel.
7.
If plumbing is to be hooked-up later be sure the dispenser is disconnected from the power source. If
plumbing has been hooked-up, the dispenser is ready for Initial Fill & Heat.

PLUMBING REQUIREMENTS

This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 90 psi (138
and 620 kPa) from a
1
" or larger supply line. A shut-off valve should be installed in the line before the dispenser.
2
Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The
1
water inlet fitting is
" flare.
4
NOTE - Bunn-O-Matic recommends
25 feet from the
1
" water supply line. At least 18 inches of an FDA approved flexible beverage tubing, such as
2
reinforced braided polyethylene or silicone, before the dispenser will facilitate movement to clean the countertop.
It can be purchased direct from Bunn-O-Matic (part number 00326-0000). Bunn-O-Matic does not recommend
the use of a saddle valve to install the dispenser. The size and shape of the hole made in the supply line by this type
of device may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the Building
Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanita-
tion Manual of the Food and Drug Administration (FDA).
L2 RED
WHITE
120V. A.C.
L1BLACK
P2185
Requires 3-wire, grounded service
rated 120/208 volts or 120/240 volts
ac, 20 amp, single phase, 60 HZ
1
" copper tubing for installations of less than 25 feet and
4
120V A.C.
208 or
240V a.c.
120V A.C.
P1841
4
L2 WHITE
240V A.C.
L1 BLACK
"A" models require 2-wire,
grounded service rated 240
volts ac, 20 amp, single
phase, 50 Hz
3
" for more than
8
P2185
27591 061500