Initial Start-Up –> Power Source
A standard furnace with A/C or a fan coil with heat pump will only have a single transformer and so only Rc is connected. It is important to note that
in these applications, Rc must be used instead of Rh like some Bryant thermostats. If the heating and cooling equipment have separate transformers,
such as a boiler with a fan coil and A/C, then both Rc and Rh are connected.
Start-Up –> Wiring -> Standard
In rare cases, the thermostat will not be able to detect certain wires. When this happens they can be added manually by selecting modify and then the
connected wires on the thermostat display.