Wiring (Miscellaneous Cover Components Of The Sewing Machine) - JUKI PS-800-8045 Instruction Manual

Active tension
Hide thumbs Also See for PS-800-8045:
Table of Contents

Advertisement

3. Wiring (miscellaneous cover components of the sewing machine)

⑪⑫⑬
⑪⑫⑬
⑨⑬
❻ ❻
7) Pressing the retaining spring of the AT
thread tension controller asm. against
the end surface of the tension controller
mounting hole, secure it with screw ❸ at
a position where the stroke of the thread
take-up spring becomes 4 to 5 mm.
If you cannot press the retaining
spring of the thread tension con-
troller asm. against the end sur-
face of the mounting hole, loosen
bracket screw ❻ of the AT thread
tension controller.
After pressing the retaining spring
against the end surface of the
mounting hole, temporarily tighten
bracket screw ❻ .
– 5 –
1) Wire AT solenoid ca-
ble ② along the route
indicated with the red
dotted line as shown
in the figure on the
left.
During this proce-
dure, change the
existing screw with
screw ⑫ . Then,
secure fixing base ⑪
with it. Then, secure
the cable with cable
clip band ⑬ .
2) Wire AT solenoid ca-
ble ② along the route
indicated with the red
dotted line as shown
in the figure on the
left.
During this proce-
dure, loosen the
screw and tighten
fixing base ⑨ . Then,
secure the cable with
cable clip band ⑬ .