KX-TG7100BXS/KX-TG7100BXT/KX-TGA710CXS/KX-TGA710CXT
11.5. Things to Do after Replacing IC
Cautions:
Since this page is common to each country, it may not apply to some models in your country. The contents below are the mini-
mum adjustments required for operation.
11.5.1. Base Unit
Before doing the following adjustment, be sure to do PC Setting (P.44) in The Setting Method of JIG (Base Unit).
BBIC
Programs for Voice processing, interface for RF and
(IC7)
EEPROM
EEPROM
Adjustment parameter data
(IC5)
(country version batch file, default batch file, etc.)
Note:
(*1) XX: country code, YY: revision number
"XX" and "YY" vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in JIG and PC
(P.44).
(*2) Refer to Check Point (Base Unit) (P.33)
11.5.2. Handset
Before doing the following adjustment, be sure to do PC Setting (P.45) in The Setting Method of JIG (Handset).
BBIC
Programs for Voice processing, interface for RF and
(IC1)
EEPROM
EEPROM
Adjustment parameter data
(IC3)
(country version batch file, default batch file, etc.)
Note:
(*3) XX: country code, YY: revision number
"XX" and "YY" vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in JIG and PC
(P.44).
(*4) Refer to Check Point (Handset) (P.36)
IC
IC
Necessary Adjustment
1. Default batch file: Execute the command "default.bat".
2. Country version batch file: Execute the command
"TG7100XXrevYY.bat". (*1)
3. Clock adjustment: Refer to Check Point (F). (*2)
1. Change the address "0000" of EEPROM to "00".
2. Default batch file: Execute the command "default.bat".
3. Country version batch file: Execute the command
"TG7100XXrevYY.bat". (*1)
4. Clock adjustment: Refer to Check Point (F). (*2)
Necessary Adjustment
1. Default batch file: Execute the command "default.bat".
2. Default batch file (remaining); Execute the command
"TGA710 DEFrevYY.bat". (*3)
3. Country version batch file: Execute the command
"TGA710XXrevYY". (*3)
4. Clock adjustment: Refer to Check Point (J). (*4)
5. 1.8 V setting and battery low detection: Refer to Check
Point (A), (H) and (I). (*4)
1. Change the address "0015" of EEPROM to "00".
2. Default batch file: Execute the command "default.bat".
3. Default batch file (remaining); Execute the command
"TGA710 DEFrevYY.bat". (*3)
4. Country version batch file: Execute the command
"TGA710XXrevYY". (*3)
5. Clock adjustment: Refer to Check Point (J). (*4)
6. 1.8 V setting and battery low detection: Refer to Check
Point (A), (H) and (I). (*4)