Do-It-Yourself Maintenance - Capital PSCT36 Use And Care Manual

Performance series
Table of Contents

Advertisement

do it yourself maintenance
WARNING!
POWER FAILURE
In the event of a power failure,
only the standard burners and
grill can be lit manually. It is
necessary to light each standard
burner individually.
If the cooktop is being used when
the power failure occurs, turn all
of the burner control knobs to the
OFF position.
Holding a match at the ports, then
by turning the control knob to the
HI position, can light the standard
burners and grill.
Wait until the flame is burning all
the way around the burner cap
before adjusting the flame to the
desired height.
INTERMITTENT OR CONSTANT
IGNITER SPARKING
Intermittent or constant sparking of the sealed
gas surface burners can result from a number
of preventable conditions. Eliminate these
conditions as indicated in the following chart.
CAUSE
SYMPTOM
Improper fit of burner cap
Intermittent Sparking
into burner base
Ceramic igniter is wet or
dirty
Knob is left in the LITE
position
Constant Sparking
Range is not properly
grounded
Electrical power supply is
incorrectly polarized
12
REMEDY
Seat cap in place.
Carefully dry or
clean igniter.
Clean ports in
burner cap with
a wire, a needle, or
straightened paper
clip.
Turn the knob to a
setting between HI
and SIM (LO on
earlier models)
Have a qualified
electrician ground
the range properly.
Refer to installation
instructions for
correct installation

Hide quick links: