3-WIRE CONDUIT INSTALLATION

6
A
Loosen the 3 lower terminal screws from
the terminal block. Insert the center bare
wire (white/neutral) tip through the
bottom center terminal block opening.
On certain models, the wire will need to
be inserted through the ground strap
opening and then into the bottom center
block opening. Insert the two side bare
wire tips into the lower left and the lower
right terminal block openings. Tighten the
screws until the wire is firmly secured (35 to
50 inch-lbs.). Do not over-tighten the
screws since it could damage the wires.
NOTE: ALUMINUM WIRING:
Aluminum building wire may be used but
it must be rated for the correct amperage
and voltage to make connection. Connect
wires according to this Step 6 or Step 7
depending on number of wires.
Terminal
block
Wire tips
Bracket
Wire used, location and enclosure of
splices, etc., must conform to good
wiring practices and local codes.
Skip to Step 8 and proceed with the
B
installation.
Installation Instructions
Conduit
9

4-WIRE CONDUIT INSTALLATION

7
A
Loosen the three lower terminal screws
from the terminal block. Remove the
ground screw and ground plate and retain
them. Cut and discard the ground strap.
DO NOT DISCARD ANY SCREWS.
Insert the ground bare wire tip between
B
the range frame and the ground plate
(removed earlier) and secure it in place
with the ground screw (removed earlier).
Insert the bare wire (white/neutral) tip
through the bottom center of the terminal
block opening. Insert the two side bare
wire tips into the lower left and the lower
right terminal block openings. Tighten the
screws until the wire is firmly secured (35 to
50 inch-lbs.). Do not over-tighten the
screws since it could damage the wires.
Before
Terminal
block
Ground
strap
After
Terminal
block
Wire tips
Ground
screw
C
Proceed to Step 8.
Ground strap
or
Neutral
terminal
Ground
plate
(grounding
to range)
Bracket

Advertisement

Table of Contents
loading

This manual is also suitable for:

Js998