Cam Chain Tensioner Inspection - Polaris RANGER 1000 2020 Service Manual

Hide thumbs Also See for RANGER 1000 2020:
Table of Contents

Advertisement

MAINTENANCE
3. If the valve clearance is not within specification, refer
to Valve Clearance Inspection page 2.33.
MEASUREMENT
Intake Valve Clearance (cold):
0.006 in (0.15 mm) ± 0.002 (0.05 mm)
Exhaust Valve Clearance (cold):
0.010 in (0.25 mm) ± 0.002 (0.05 mm)
4. Repeat steps 1-3 until all valves have been
inspected.
REASSEMBLY
1. Install the valve cover. Refer to Valve Cover Service
page 3.35.
2. Install the spark plugs. Refer to Spark Plug Service
page 4.20
3. Install the outer clutch cover. Refer to PVT Clutch
Cover Service page 6.7.
4. Connect the black negative battery cable to the
battery.
TORQUE
Battery Terminal Fastener:
40 in-lbs (5 Nm)
5. Start the engine to ensure proper operation.
2.34

CAM CHAIN TENSIONER INSPECTION

1. Locate the cam chain tensioner on the MAG side of
the engine near the starter.
2. Remove the plunger bolt
3. Remove the two tensioner mounting bolts
tensioner gasket.
4. Push on the tensioner lock
plunger in and out. It should move freely. If it does not
move freely, replace the tensioner assembly.
9850045 R01 - 2020-2021 RANGER 1000 Service Manual
q
and the spring.
w
and
e
and manually move the