Troubleshooting And Fault Repair / Faq - Beko BEKOMAT 16i CO Translation Of Original Installation And Operation Manual

Table of Contents

Advertisement

BEKOMAT
®
16i CO

15. Troubleshooting and fault repair / FAQ

Error or fault pattern
n = ∞
72 | 76
Possible causes
Negative power-on self-test.
0 The electronics unit is
defective.
All LEDs are off.
All LEDs are permanently lit.
No condensate is drained after
the TEST button has been
pressed.
The condensate is only drained
when the TEST button is
pressed.
The BEKOMAT
discharges
®
continuously.
Original installation and operation manual
Troubleshooting
Contact BEKO TECHNOLOGIES customer
service (see "1.1 Contact" on Page 5).
Read off the operating voltage on the type 
plate and check it.
Check whether voltage is applied to the
terminals of the power control board (GND,
+24 VDC).
Check the connection terminals on the power
control board.
Disconnect the product from the voltage
supply and reconnect after >5 seconds.
Inspect the circuit board for potential
damage.
Check the feed line and the drain line.
Replace wear parts.
Check the valve function by pressing the
TEST button.
0 Valve switching can be heard clearly
(clicking sound).
Check the connection terminals on the
control circuit board.
Install the feed line at a slope >3 %.
Fit venting line.
Check whether the necessary minimum
pressure has been reached (see "4. Technical
data" on Page 25).
Replace wear parts.
Clean the complete valve unit.
Replace wear parts.
Clean the sensor tube.