Appendix B Design Verification Test Procedure
1.Purpose
This standard establishes the environmental specification for projector related
products, which defines the level of product performance and reliability in the field. It is not
necessary the intent of these specification to simulate a typical user environment, but rather
to provide for a level of product robustness that when applied over a wide range of
manufacturing variability and environmental usage conditions.
2.Test Summary
Dynamic Testing
Package Drop
Package Vibration
Shock, non-operating
Security Lock
Fragility
Atmospherics
Temperature/Humidity,
operating
Temperature/Humidity,
non-operating
Altitude, operation
Safety/EMC
UL/cUL
TUV Rheinland
Fcc/CE/C-Tick
All manuals and user guides at all-guides.com
76cm, 1 drop per orientation, all 6 primary surfaces, plus a selected
corners, and three selected edges, total of 10 drops
Random , 0.01g2/Hz, 5~100Hz, all primary axis, 20 min per orientation,
total of 60min
Sine, 0.5g, 5~200Hz, 1 octave/min, 15 min dwell on each resonant
frequency, all primary axis, one sweep (30min minimum) per orientation,
total of 90+min
50g, 20ms half-sine, all primary axis, 1 shock per orientation, total of 3
shocks
150N break away force
Shock, 50g, 20ms half-sine, all primary axis, 1 shock per orientation, total
of 3 shocks
Accelerate Life Test (operating), 65 o C, 72hr
Thermal shock(bare board), -65~125 o C, 48hr
Input Voltage, 90~264V
Input RGB signal, 0.7V±0.1
10~35 o C/10~80RH, 48hr
-10~70 o C/10~80RH, 48hr
0~6000ft@30 o C, 4hr
Specification
13