3-4.5
CW index delay menu (includes the DMD bias voltage)
(Press Hot Keys; then, press "Return"+"Left" key simultaneously)
C/W index delay
DMD bias voltage
White peaking
Gamma table
CSC table
GAM
CSC
Key :
Up / Down
Left / Right
Setup
a.) CW index adjustment
Procedure :
Choose the C/W index delay.
Adjust a value.
Range is from 0 to 719.
Default value is 200.
Test Pattern : RGBW 64 scale.
b.) DMD bias voltage adjustment
Procedure :
Choose the DMD bias voltage.
Adjust a value.
Range is from B to E.
DMD Chip Default value is E.
c.) Save data to EEPROM
Procedure :
Push Up / Down / Left / Right at the same time.
If these key inputs are accepted, all LEDs light orange.
x
x
x
x
x
On
On
Choose an item with cursor
Adjust a value / Choose a setting
Initialize adjustment values
Off
Off