GE WPRE6100 Technical Service Manual page 27

Profile washers with electronic control and mode shifter assembly
Hide thumbs Also See for WPRE6100:
Table of Contents

Advertisement

https://appliancetechmanuals.com
Tub Cover
Note: The tub cover can be replaced without
removing the tub.
To remove the tub cover:
1.
Remove the front panel. (See
2.
Remove the cover/lid assembly. (See
).
Assembly
3.
Disconnect 4 dampening straps from the tub
cover by removing four
4.
Release the cover from the outer tub by lifting
the 8 tabs.
5.
Raise the front of the cover to clear the front
cabinet brace and tilt the tub forward.
6.
Carefully lift and remove the cover from the tub.
).
Front Panel
Cover/Lid
-in. hex-head screws.
/
5
16
Tub Cover
Tab (1 of 8)
Tub Assembly
Note: The motor can be replaced without removing
the tub. (See
Inverter/Motor.
be removed when replacing the spin basket, outer
tub, or certain speed drive components.
To remove the tub assembly:
1.
Disconnect power.
2.
Lower the drain hose into a small bucket to
remove any water remaining in the tub.
3.
Remove the front panel. (See
4.
Remove the cover/lid assembly. (See
)
Assembly.
5.
Remove the tub cover. (See
6.
Remove the agitator. (See
7.
Remove the
-in. hex-head bolt and air bell
/
7
16
coupling from the agitator shaft.
8.
Remove the air bell.
Note: When replacing air bell, tighten the
head bolt to 90 in. lbs. of torque.
– 27 –
) The tub assembly must
)
Front Panel.
Cover/Lid
.)
Tub Cover
.)
Agitator
-in. hex-
/
7
16
(Continued next page)