Water Valve
The water valve is a 120 VAC, dual solenoid type,
and is accessed by placing the control panel in
the service position. It is inserted and retained in
a cutout in the rear of the backguard and held in
place by 2 hex-head screws. It is only available as a
complete assembly.
The water valve has a flow rate of 2.1 gallons (8
liters) per minute.
If the pressure switch is not satisfied within 20
minutes, a fill error code will be recorded. If the
pressure switch has not opened in 45 minutes,
the main control will de-energize the water valve
and place the washer in pause mode.
Each solenoid coil has an approximate
resistance value of 1.1K Ω.
To remove the water valve:
1.
Disconnect power.
2.
Place the control panel in the service position.
(See
Control Panel
3.
Remove the fill hoses from the water valve.
4.
Disconnect the white wire harness from the hot
water (H) solenoid valve.
5.
Disconnect the red wire harnesses from the cold
water (C) solenoid valve.
Note: The fill funnel hose is difficult to remove.
6.
Remove the fill funnel hose. Squeeze the clamp
and slide it back. Carefully break the hose loose
by inserting a small flat-blade screwdriver under
the hose to break the seal.
.).