Maintenance and service

13 Maintenance and service

13.1 Overview: Maintenance and service

13.2 Maintenance safety precautions

13.3 Checklist for yearly maintenance of the outdoor unit

13.4 Checklist for yearly maintenance of the indoor unit

Installer reference guide
166
NOTICE
Maintenance MUST be done by an authorised installer or service agent.
We recommend performing maintenance at least once a year. However, applicable
legislation might require shorter maintenance intervals.
This chapter contains information about:
The yearly maintenance of the outdoor unit
The yearly maintenance of the indoor unit
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
NOTICE: Risk of electrostatic discharge
Before performing any maintenance or service work, touch a metal part of the unit in
order to eliminate static electricity and to protect the PCB.
Check the following at least once a year:
Heat exchanger
The heat exchanger of the outdoor unit can get blocked up due to dust, dirt,
leaves, etc. It is recommended to clean the heat exchanger yearly. A blocked
heat exchanger can lead to too low pressure or too high pressure leading to
worse performance.
Check the following at least once a year:
Water pressure
Water filters
Magnetic filter/dirt separator
Water pressure relief valve
Relief valve hose
EPGA11~16DAV3(7) + EAVZ16S18+23DA6V(7)+9W
Daikin Altherma 3 H F
4P556075-1A – 2021.09