Quick Links

ULTRA SILENT
VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
To register this product visit:
www.broan.com
Installer: Leave this manual with the homeowner.
TM
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the motor with the exact service motor. The impeller should also
be replaced.
OPERATION
Use an on/off switch or speed control to operate this ventilator. See
"Connect Wiring" for details. Use of speed controls other than the
Broan Models 78V and 78W may cause a motor humming noise.
WARRANTY
BROAN THREE YEAR LIMITED WARRANTY
Broan warrants to the original consumer purchaser of its products that such
products will be free from defects in materials or workmanship for a period
of three years from the date of original purchase. THERE ARE NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE.
During this three-year period, Broan will, at its option, repair or replace,
without charge, any product or part which is found to be defective under
normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS AND TUBES. This warranty does not cover (a) normal main-
tenance and service or (b) any products or parts which have been subject
to misuse, negligence, accident, improper maintenance or repair (other
than by Broan), faulty installation or installation contrary to recommended
installation instructions.
The duration of an implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation
on how long an implied warranty lasts, so the above limitation may not
apply to you.
BROAN'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN'S OP-
TION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY
UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCI-
DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF
OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan at the address
or telephone number stated below, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC Hartford, Wisconsin
www.broan.com 800-558-1711
MODEL QTRE080R
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Broan ULTRA SILENT QTRE080R

  • Page 1 (other than by Broan), faulty installation or installation contrary to recommended installation instructions. The duration of an implied warranty is limited to the three-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN’S OP- TION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCI- DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
  • Page 2: Typical Installations

    TYPICAL INSTALLATIONS A mounting frame is provided to allow for accurate positioning of the fan anywhere in the room. It can be used with I-joists, standard joists and trusses, from 16” to 24” on-center. Housing mounted anywhere between I-joists using mounting frame. Housing mounted anywhere between standard joists using mounting frame. Housing mounted anywhere between trusses using mounting frame. MODEL QTRE080R PLAN THE INSTALLATION COOKING AREA Do not install above or inside this area.
  • Page 3: New Construction Installation

    NEW CONSTRUCTION INSTALLATION INSTALL MOUNTING FRAME & HOUSING TABS FRAMING MEMBER DUCT CONNECTOR DUCT CONNECTOR BRACKET 1. Hold one side of the mounting frame so the tabs touch the bottom edge of the framing member. Nail or screw mounting frame in place. Extend the mounting frame to the opposite framing member, and nail or screw in place. 2. Snap the duct connector onto the duct connector bracket. Attach the duct connector bracket to the mounting frame using the screw provided. Position the bottom edge of the duct connector bracket so it will be flush with the finished surface of the ceiling and tighten the screw. 3. Position the two movable brackets of the mounting frame directly across from each other and insert the housing into the mounting frame until it touches the duct connector bracket. Secure the housing to the mounting frame and duct connector bracket using the (5) screws provided. Position the housing horizontally as desired. INSTALL DUCTWORK 4. Connect 4” round ductwork to duct connector. Run ductwork to a roof cap or wall cap. Tape all ductwork connections.
  • Page 4 INSTALL THUMBSCREW & GRILLE EXISTING CONSTRUCTION INSTALLATION REMOVE EXISTING FAN WARNING Before removing existing fan, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. EXISTING CEILING 11” FRAMING 1. Enlarge the ceiling opening around the existing fan to 11” x 12 ”. The 11” dimension should run parallel to the ceiling framing. 2. Carefully remove the existing fan housing from the ceiling. Disconnect the ductwork and electrical wiring from the housing and leave them in place above the ceiling. 6. Install thumbscrew through flange of motor plate as THUMBSCREW shown. 7. Install ceiling material. Cut out around housing. 8. Squeeze grille springs and insert them into slots on each side of housing. Push grille against ceiling.
  • Page 5: Connect Electrical Wiring

    MOUNTING FRAME DUCT CONNECTOR SCREW BRACKET (provided) 5. Attach the duct connector bracket to the mounting frame using the (1) screw provided. Position the bottom edge of the duct connector bracket so it touches the finished surface of the ceiling and tighten the screw. CONNECT ELECTRICAL WIRING 6. Retrieve the existing electrical wiring from above the ceiling and use a UL approved connector to secure it to the wiring plate. Re-attach wiring plate to fan housing, if necessary. Connect wires as shown in wiring diagrams. INSTALL HOUSING EXISTING ELECTRICAL WIRING WIRING PLATE (shown removed from fan housing) 7. Position the two movable brackets of the mounting frame directly across from each other and insert the housing into the mounting frame until it touches the duct connector bracket. Secure the housing to the mounting frame and duct connector bracket using the (5) screws provided. INSTALL THUMBSCREW &...
  • Page 6: Service Parts

    97017853 Blower Assembly 97016497 Grille Assembly (includes key no. 8) 99140199 Grille Spring (2 req’d) 98010614 Duct Connector Bracket 10 97018138 Frame Assembly 11 99420665 Thumbscrew, #8-18 x .375 Order service parts by “Part No.” - not by “Key No.” SERVICE NOTE To remove Blower Assembly: Unplug motor. Remove thumbscrew (11) from motor plate flange. Find the single TAB on the motor plate (located next to the receptacle). Push up near motor plate tab while pushing out on side of housing. Or insert a straight-blade screwdriver into slot in housing (next to tab) and twist screwdriver. Replacement parts can be ordered on our website. Please visit us at www.broan.com MODEL QTRE080R Page 6...