rEAD AND SAVE tHESE INStrUCtIONS
WArNING
tO rEDUCE tHE rISK OF FIrE, ELECtrIC SHOCK, Or IN-
JUrY tO PErSONS, OBSErVE tHE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the ser-
vice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
CAUtION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with the homeowner.
MODELS qtr050F • qtrE080 • qtrE110
to register this product visit:
www.broan.com
CLEANING & MAINtENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
OPErAtION
Use an on/off switch or speed control to operate this ventilator. See
"Connect Wiring" for details. Use of speed controls other than the
Broan Models 78V and 78W may cause a motor humming noise.
WArrANtY
Broan warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for
a period of three years from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan will, at its option, repair or replace,
without charge, any product or part which is found to be defective under
normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS AND TUBES. This warranty does not cover (a) normal main-
tenance and service or (b) any products or parts which have been subject
to misuse, negligence, accident, improper maintenance or repair (other
than by Broan), faulty installation or installation contrary to recommended
installation instructions.
The duration of an implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation
on how long an implied warranty lasts, so the above limitation may not
apply to you.
BROAN'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN'S OP-
TION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY
UNDER THIS WARRANTY. BROAN SHALL NOT BE LIABLE FOR INCI-
DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF
OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan at the address
or telephone number stated below, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC Hartford, Wisconsin
www.broan.com 800-558-1711
BrOAN tHrEE YEAr LIMItED WArrANtY
Page 

Advertisement

loading

Summary of Contents for Broan qtr050F

  • Page 1 WArrANtY 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip- ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those BrOAN tHrEE YEAr LIMItED WArrANtY published by the National Fire Protection Association (NFPA), Broan warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for and the American Society for Heating, Refrigeration and Air a period of three years from the date of original purchase. THERE ARE Conditioning Engineers (ASHRAE), and the local code authori- NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT ties. NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
  • Page 2: Typical Installations

    MODELS qtr050F • qtrE080 • qtrE110 Page  tYPICAL INStALLAtIONS Housing mounted anywhere Housing mounted between trusses to I-joists. using hanger bars. PLAN tHE INStALLAtION Housing mounted anywhere between I-joists COOKING AREA Do not install above or using inside this area.
  • Page 3 MODELS qtr050F • qtrE080 • qtrE110 Page  INStALL HOUSING & DUCt 1a. Mount SCREW (2) HOLE FOR OPTIONAL housing to SCREW MOUNTING (4) joist or I-joist. Use a pliers to bend housing tABS out to 90 . Hold housing in place so that TABS the housing tabs contact the bottom of the joist. The housing mounts with four (4) screws or nails. Screw SPACER or nail housing to (use for mounting to I-Joist) joist through lowest BOTTOM EDGE holes in each...
  • Page 4: Service Parts

    MODELS qtr050F • qtrE080 • qtrE110 Page  CONNECt WIrING INStALL GrILLE 5. Finish ceiling. Install ceiling material. Cut out around housing. 6. Attach grille to housing. Squeeze grille springs and insert them into slots on each side of housing. 7. Push grille against ceiling. 4. Connect electrical wiring. Run 120 VAC house wiring to installation location. Use proper UL approved connector to secure house wiring to wiring plate. Connect wires as shown in wiring diagrams. SErVICE PArtS Key No.

This manual is also suitable for:

Qtre110Qtre080Qtr050f